Overview

The Uponor Heat and Cool
Thermostat (A3030102) controls
hydronic heating, air conditioning
and a fan. The six-wire thermostat
receives power from the Rh (radiant
heating) and C (cooling) terminals.

These thermostats are power-
sharing, meaning they receive power
for operation by sharing voltage
with the connected wiring. This
eliminates any need for a third wire
or batteries, making them simple to
install, wire and service.

Note:

Uponor thermostats work

effortlessly with other Uponor
components. However, some
commonly used third-party devices
(e.g., relays, zone valves, etc.) may
have compatibility issues with these
thermostats. If connecting the
Uponor thermostat to a third-party
control device, refer to that device’s
installation instructions for specific
information regarding operation
with power-sharing thermostats. The
Typical Wiring Schematics section on

page 5

features the most common

wiring applications. For additional
help, contact Technical Services. 

Uponor U.S.: (800) 321-4739

Uponor Canada: (888) 994-7726

Tools Required

• Small, flat-head screwdriver

• Phillips screwdriver (for

mounting hardware)

• Wire stripper and cutter

Installation

To properly install the thermostat,
refer to the following instructions.

1. Thoroughly read this instruction

sheet to understand the proper
procedures for installation and
operation. Failure to do so could
result in damage to the
thermostat or its connected
equipment, and can also create
a safety hazard.

2. Ensure the function and rating

of the thermostat is suitable for
the application.

3. Only experienced and trained

professionals familiar with low-
voltage wiring should attempt to
install the thermostat.

4. Uponor recommends using

18AWG LVT wiring for all 
low-voltage connections 
(as regulated by local 
building codes).

Placing the Thermostat

Thermostat placement is extremely
important. Install the thermostat
approximately five feet (1.75
meters) above the floor on a
smooth, flat surface. Avoid
mounting the thermostat in the
following locations.

• Near or around windows

• On outside walls

• Near fireplaces

• In the corner of a room

• Behind doors

• On interior walls susceptible 

to solar gains

• Near stoves, lamps, 

televisions, etc.

• Damp areas

Technical Data

Operating Voltage

24VAC +/- 10%

Maximum Load

1.3 Amps at 24VAC
4 x MVA (part number A3020522) 
6 x TVA (part number A3010522)

Display Range

38°F to 99°F (2°C to 37°C)

Setting Range

38°F to 99°F (2°C to 37°C)
68°F (20°C) heating default 
setting 
75°F (24°C) cooling default 
setting

Minimum Limit

38°F (2°C) to maximum limit
50°F (10°C) default minimum 
setting

Maximum Limit

Minimum limit to 99°F (37°C)
86°F (30°C) default maximum 
setting

Units

User-configurable Fahrenheit or 
Celsius

Memory

Permanent settings and mode 
without power

Freeze Protection

Activation at 38°F (3.3°C)
De-activation at 39°F (3.8°C)

Overheat 

Activation at 100.4°F (38°C)

Protection

De-activation at 98.6°F (37°C)

Resolution

1° displayed
0.25° calculated

Temperature

Shipping and storage: 14°F to

Ranges

158°F, (-10°C to 70°C)
Operation: 32°F to 104°F, 
(0°C to 40°C)

Humidity

20 to 90% non-condensing

Size

5" H x 2.72" W x 0.91" D