background image

Button Placement

RESET

- resets programs and clock to

factory settings

SET CLOCK
ECONO
PROGRAM

UP/DOWN
AHEAD/BACK
HOLD

USAGE

- activates ECONO mode programs

- scrolls through program

settings

- sets program temperatures

- sets program times

- disables all programs and keeps

temperature constant

- displays the accumulated system

“ON” time

OPERATION

LCD Display

Press the

button to activate or de-activate the ECONO

mode programs. The “ECONO” symbol will appear on the screen
when the ECONO mode is activated.

ECONO

2

Press the

button again to

view USAGE THIS WEEK.

USAGE

1

Press the

button once to

view USAGE TODAY.

USAGE

*

- USAGE TODAY automatically resets itself daily at midnight.
- USAGE THIS WEEK automatically resets itself at the end of the week

at 00:00:00.

- A new week begins Monday morning.

Days Of The Week
Clock Display; Usage Display
Usage Monitor Function
Temperature Units (
Current Temperature
Heat “ON” Indicator
Program Number
Set Temperature
Power Failure Indicator
HOLD Function
ECONO Mode

C or

°

°F)

Programmable Thermostat

HTM311A

DISPLAY / BUTTONS

2

ECONO MODE

OWNER’S

MANUAL

Read and understand this
manual before installation or
use.

FEATURES

!

!

!

!

!

!

!

!

!

!

Ideal for electric baseboards,
convectors and radiant ceiling
heaters
5+1+1 day programming
ECONO mode
12/24 hour clock
Temperature display (
Usage Monitor - keeps track
of accumulated “ON” time
Simple 2-wire installation
Rating: 240V AC, 60Hz

MAXIMUM LOAD: 15A
- 3600W @ 240V
MINIMUM LOAD: 750W

°C or °F)

4

6

11

C

F

C

F

P2

P3 P4

P1

MO TU WE TH FR SA SU

AM

PM

USAGE TODAY THIS WEEK

HOLD ECONO

*

4

1

2

3 5

7

6

1

2
3
4

5
6
7

8

8

1
2
3
4
5
6
7
8
9

10
11

2
3

Press the

or

button to

toggle the time forward or back.

AHEAD

BACK

Press the

button to start setting.

PROGRAM

1

Press the

button to enter the ECONO mode.

ECONO

4

Press the

or

button to

toggle the SET temperature up or down.

UP

DOWN

5

Press the

button for day setting.

The day will be blinking.

SET CLOCK

6

Press the

or

button to

select the day.

AHEAD

BACK

7

Press the

button to

advance to the next program setting
and repeat steps

.

PROGRAM

3

6

C

C

P1

MO

AM

*

CAUTION!

Maximum load for this thermostat is 15A, 3600W resistive. DO NOT
exceed this limit; otherwise a potential fire hazard exists.

TO AVOID FIRE, SHOCK, OR DEATH, SHUT OFF POWER SUPPLY AT
THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS
OFF BEFORE WIRING.

This product operates at 208/240V AC. Do not install it unless you are
completely familiar and competent with house wiring. Handle with
caution to prevent any risk of electrical shock that could cause serious
injury or death.

For wiring, use COPPER conductors only.

All wiring must comply with applicable codes and regulations.

DO NOT connect voltage different from device rating. This thermostat
will not operate at 120V AC.

Ensure that the heating system is protected by appropriate circuit
breakers or fuses.

INSTALLATION

2

3

Mount the new thermostat into
the wall box using the two
screws provided through the
mounting holes. (Remove the
cover if necessary).

Using the wire nuts provided,
securely fasten each wire from
the new thermostat to a wire in
the wall box. Refer to the
diagram.

NOTE: ENSURE NO

BARE WIRE IS EXPOSED.

1

Remove the old thermostat
carefully and identify the two
wires from the wall box.

4

Reconnect power supply.

DISCONNECT THE POWER SUPPLY AT THE CIRCUIT BREAKER OR
FUSE BEFORE PROCEEDING WITH THE INSTALLATION.

*

SETTING THE TEMPERATURE DISPLAY ( C

F)

or

You will now have 16 seconds to set the temperature display to C or F by
pressing the

or

button. (Factory Default = C).

UP

DOWN

If necessary,

the

button may be pressed after 16 seconds to start over.

RESET

°

°

°

°

°

*

Wire Nut

2-Wire Installation:

Wall Box

4-Wire Installation:

Wire Nut

Wall Box

208/240V AC
Line

Electric
Baseboard
Heater

Electric
Baseboard
Heater

208/240V AC
Line

9

10

1

5

7

8

3

The ECONO mode consists of 2 program settings. You can basically use this
function for an installation at a cottage/vacation home. The 2 program settings
run on a weekly basis. One setting is used to raise the temperature to a
comfortable level while you are there at the cottage, and the second setting is to
bring the temperature back down for energy savings while the cottage is vacant
during the rest of the week.

FOR EXAMPLE:

If you go to your cottage only during the weekends, then you can set the ECONO
programs as such:

P1 - SATURDAY - 8:30 am for 21 C; and,
P2 - SUNDAY - 5:00 pm for 15 C

This means the cottage will be heated at 21 C between Saturday morning at
8:30 am to Sunday evening at 5:00pm. For the rest of the week from Sunday
evening at 5:00 pm to the next Saturday morning at 8:30 am, the cottage will be
kept at a low temperature level of 15 C for energy savings.

°

°

°

°

By default the ECONO mode is pre-programmed as follows:

P

TIME

P1

P2

3:00 pm

10:00 pm

15.0 C (59.0 F)

o

o

16.0 C (61.0 F)

o

o

FRIDAY

ECONO MODE

To set the ECONO mode programs, follow the steps below:

OPERATION

CURRENT TEMPERATURE DISPLAY

The current (room) temperature is displayed
in the center panel of the LCD screen.

HEAT “ON” INDICATOR

The thermostat displays the

symbol when

the heating system is ON and turns it off when
the heating system is OFF.

TEMPORARY OVERRIDE

To change the temperature temporarily,
press the

or

button to set the desired temperature. The thermostat

will return to the regular program at the next scheduled program time.

UP

DOWN

HOLD FUNCTION

This feature is used to hold the thermostat at a constant temperature and
disable all set programs until released.

- Press the

button once and use the

or

button to set the

desired hold temperature. The “HOLD” symbol will appear on the screen
to indicate that the HOLD function is active.

HOLD

UP

DOWN

- To cancel the HOLD function, press the

button again. The “HOLD”

symbol will disappear and the thermostat will return to the programmed
temperature.

HOLD

C

C

P1

FR

PM

ECONO

PROGRAMMING
FOR FRIDAY

PROGRAM
TIME

SET
TEMPERATURE

PROGRAM
NUMBER

ECONO

USAGE MONITOR

This thermostat tracks the system “ON” time, or
the time the heating equipment is running.

C

C

P1

USAGE TODAY

USAGE
DISPLAY

USAGE
MONITOR
FUNCTION

HEAT “ON”
INDICATOR

CURRENT
TEMPERATURE

SET
TEMPERATURE

HOLD

C

C

MO

AM

HOLD

MEMORY BACKUP / POWER FAILURE INDICATOR

This thermostat is equipped with a built-in rechargeable
battery. The internal battery serves to protect the time
and program settings in the case of a power failure.
Under normal conditions the memory will be retained
for several days if the power goes out for that long.

In the event of a power failure, the

symbol will

appear on the screen and the time will continue to run.

MO

AM

POWER
FAILURE
INDICATOR

TIME

PAGE 1

PAGE 2

PAGE 3

PAGE 4

PAGE 8

PAGE 9

PAGE 10

PAGE 11