Device Registration

in the Uplink Dealer Portal

Register your company at 

www.uplinkdealers.com

 or use your existing 

account to login.

Adding preferred monitoring station

Contact your monitoring station and request your Uplink Dealer Code.
•  Specify your preferred monitoring station during your initial registration in 
    the list found in section “Additional Information” > “Preferred Monitoring   
    Station.”
    Provide your Dealer code in the corresponding field, 

OR

•  Add preferred monitoring station/s after registration from 
    My Devices > Monitoring Stations > Add CMS

Add a new device and choose cellular service monthly billing method:

Use the device Serial Number and the Config Key provided with this manual. 
•  Go to My Devices > Devices > Add New Device.
•  Select monitoring station (optional)
•  Select preferred cellular service monthly billing method.
•  From Monitoring Station  – You will be billed for cellular service by the   
    monitoring station.
•  From Uplink – You will be billed for cellular service by Uplink.

Uplink 5500M

Universal Cellular Communicator

Quick Installation Manual

WARNING: The wiring should be done only when the panel and the  

 

communicator are disconnected from the powerline!

 

Connect the antenna and place it outside of the alarm panel’s box.

 

C and – of the communicator to a max of 12V - 29V DC power supply.

LED Indicator

 

Slow flashing – trying to establish connection

 

Constantly On – connection established at good signal level

 

Constantly On, blinking every 5 sec. – connection established at low signal level

 

Fast flashing – sending cellular traffic

Default configuration of the digital inputs and outputs

IN1      General Alarm - Zone 251 

OUT1    Preconfigured as Pulse Output

IN2      General Alarm - Zone 252 

OUT2    Preconfigured as Pulse Output

IN3      General Alarm - Zone 253

IN4      General Alarm - Zone 254

The inputs are tripped by applying a negative (GND) signal and must share the same 

common ground.

All inputs can be connected to bell output and will recognize a pulsed voltage 

as Fire Alarm and steady voltage as General Alarm. Always use the active 

output of the bell  and wire it to the alarm panel  according to the bell supervision 

requirements – refer to the alarm panel installation manual.

Changing the configuration of the digital inputs and outputs (Optional)

Note: The device should be powered up and connected to the network.

Changing the configuration from the Uplink Dealers Portal:

 

Open the “Device Dashboard” and navigate to “Advanced Settings”

 

Check the “Enable Online Settings” checkbox and press “Get Current Settings”

 

Change the settings of the digital inputs and outputs under the “Pins” section

Changing the configuration from the RControl Admin App:

 

Go to the “Settings” tab and navigate to “Advanced Settings”

 

Enable “Editing”

 

Change the settings of the digital inputs under the “Inputs” section

(+):  

   12-29 VDC Power Supply

(-):  

   Ground  

IN1:  

   Digital Input 1 (pull-up to VDC)

IN2:  

   Digital Input 2 (pull-up to VDC)

IN3:  

   Digital Input 3 (pull-up to VDC)

IN4:  

   Digital Input 4 (pull-up to VDC)

OUT1:  

   Latched/Pulse Output (transistor, open collector, 100mA)

OUT2:  

   Pulse Output (transistor, open collector, 100mA)

v.01-2022-11-05_5000