Uotek UT-217E User Manual Download Page 1

RS-232/RS-485/RS-422 UT-217E 

NO Power Photoelectric Isolation 

Interface Converter 

User Manual

The converter is applicable for all the existing communication 

software and interface hardware without any software modifications 

for the previous working mechanism based on RS-232.

      A reliable and stable point-to-point and point-to-multipoint 

communication can be ensured by UT-217E photoelectric isolation 

interface converter. For point-to-multipoint communication, as 

many as 32 interface facilities of RS-422 or RS-485 standard can 

be connected to each converter, and a high data transmission rate 

of 300-115.2KBPS can be achieved. Power indicator light and 

data traffic indicator light are also available with the converter 

for malfunction indication. Two conversion communication modes 

including RS-232 to RS-422 and 

RS-232 to RS-485 are supported.

II. Performance parameters

1. Interface characteristic: compatible with the standards of 

    RS-232C and RS485/RS-422 issued by EIA/TIA.

2. Electric interface: DB9 female connector for RS-232 interface 

    input end, RJ-45 and 4PIN connector for RS-422/RS-485 interface 

    output end.

3. Protection grade: +/-15KV ESD protection for RS-232 interface, 

    and 600W surge protection each line for RS-422 and RS-485 

    interfaces.

4. Isolation degree: isolation voltage 2500Vrms 500DC non-stop.

5. Operation mode: asynchronous half duplex or asynchronous 

    full duplex.

6. Signal indication: 3 pilot lamps for Power (PWR), Send (TXD) 

    and Receive (RXD).

7. Transmission media: twisted pair cable or shielded cable.

8. Transmission rate: 115.2K BPS to 300M, 38.4K BPS to 2.4KM 

    and 9,600 BPS to 5KM.

9. Dimensions: 93mm 74mm

22mm.

10. Working circumstance: -40 to 85

, relative humidity 5%-95%.

11. Transmission distance: 0-1,200meters (115,200bps-9,600bps).

III. Connector and signal

    RS-232C bay-line distribution 

Earth protection

Receive data SIN(RXD)

Send data SOUT (TXD)

Data terminal ready DTR

Ground signal GND

Data setting ready DSR

Request send RTS

Clear send CTS

Ring indication RI

1

2

3

4

5

6

7

8

9

    DB 9  Female

(PIN)

RS-232C Interface signal

IV. Hardware installment and application 

Read the user manual carefully before installing the 
U T - 2 1 7 E  p h o t o e l e c t r i c   i s o l a t i o n  i n t e r f a c e   c o n v e r t e r.  
Connect the attached communication cable to RS-232 
interface, and insert the power supply converter to power 
socket. The product adopts the DB-9/RJ-45 general used 
connector for input and output interface without jumper 
setting for RS-485 or RS-422 automatic communication 
mode. Either twisted pair cable or shielded cable is 
a p p l i c a b l e   f o r  e a s y   i n s t a l l a t i o n  o r   u n - i n s t a l l a t i o n . 
T/R+T/R-represents sending and receiving the A+/B-, 
R X D + / R X D -   r e p r e s e n t s  r e c e i v i n g   t h e  A + / B - , V C C 
represents power input or output, GND represents public 
underground line. Point-to-point and point-to-multipoint 

RS-485/RS-422 output signal and connector end 
bay-line distribution

88

11

RJ-45 bay-line distribution 

  4PIN

(PIN)

 Output signal

 

   RS-422 

full-duplex

 connection

 

  

   RS-485 

half-duplex 

connection

T/R+

T/R-

RXD+

RXD-

GND

Send(A+)

Send(B-)

Receive(A+)

Receive(B-)

Underground line

RS-485 (A+)

RS-485 (B-)

None

None

Underground line

RJ-45

1

2

3

6

4.5.7.8

1

2

3

4

1

2

3

      Compatible with the Recommended Standards of RS-232C, 

RS-422 and RS-485

 UT-217E photoelectric isolation interface 

converter can convert the single-ended RS-232 signal into

balance differe nced RS-422 or RS-485 signal. The built-in

photoelectric isolator can provide an isolation voltage of as high 

as 2500Vrms. Also, there is a rapid transient voltage suppression 

protector for protec tion of RS-422/RS-485 interface with advanced 

TVS(TRANSIENT VOLTAGE SUPPRESSOR) technology 

adopted. Under normal conditions, the TVS tube is in the state 

of high resistance. However, when both ends of the TVS tube are 

hit by a transient high energy, the impedance at both ends can be 

depressed by the TVS at a very high speed, and after absorbing a

high current, the volt age between the two ends is suppressed 

and kept at a pre-set value, therefore no damage is caused to the 

electrical components behind by the transient high voltage impact. 

The protector can effectively restrain lightning or ESD (electro 

static discharge) with a protection voltage of 600W on each line

for lightning surge and surge voltage or transient over voltage 

possibly caused up by various reasons, and  at the same time, a 

high-speed tra nsmission of RS-422/RS-485 interface is ensured 

by the tiny capacitance between the poles. Through a DB9 female 

connector RS-232 interface is connected to other interfaces 

compatible wit h RS-232C standard, and for RS-422 and RS-485 

interfaces RJ- 45 and 4PIN connector is to be used for connection. 

The unique I/O circuit of the internal zero delay auto transceiver 

contained in the converter controls the data stream direction 

automatically without any handshaking signal (for example RTS, 

DTR etc). The converter is plug-and-play without any jumper 

settings needed for mode shift between full duplex (RS-422) 

and half duplex (RS-485). 

I. Summary

Reviews: