English
Checks
- The copper jumper and the electrical cable must be secured together beneath the screw in its tightening direction; and
the electrical connections must be well secured before connecting the appliance to the mains electricity .
- check for any electrical dispersion between the phases and the ground, and for electrical continuity between
UIFFYUFSOBMDBTJOHBOEUIFNBJOHSPVOEMJOF
- Check that the power supply voltage does not deviate from the nominal voltage value specified on the
appliance rating plate when the appliance is operating.
If this is not the case, wire the phases as specified on
the "technical specifications" sheet attached.
Adapting to different voltage
'PSFMFDUSJDBMBOEWPMUBHFSFRVJSFNFOUTUIBUEJòFSGSPNTUBOEBSEWBMVFT 7_1)/1&)[JUJTOFDFT
-
sary to replace the power supply cable and connect the new cable to the terminal board following the diagrams on
the
i5FDIOJDBMTQFDJöDBUJPOTwTIFFU
1PXFSTVQQMZ$POOFDUJPO%JBHSBN
attached to the appliance.
Replacing the power supply cable
The cable must be replaced by UNOX or by
its technical assistance service, and in all
cases by a person with similar qualification
in order to avoid possible risks.
Follow the procedures below to replace the power
supply cable:
- open the cover of the terminal board by releasing the
two bottom tabs;
- remove the cable installed by detaching it from the
terminal board;
-
consult
the
i5FDIOJDBMTQFDJöDBUJPOTwTIFFU
POWER
SUPPLY-CONNECTION DIAGRAM):
the sheet indi-
cates all possible wiring diagrams and the specifica-
tions that the new cable must have in reference to
the wiring selected
$BCMF5ZQF
;
- re-connect the cable;
- Close the terminal board cover again