b- The appliance must be connected to the
round line of the network.
Moreover, the appliance must be inclu-
ded in an equipotential
system whose efficiency
must be properly checked
according to the current
law. This connection must
be done between the dif-
ferent appliances using the
terminal marked with the
symbol:
The equipotential conductor must have a
minimum section of 10 mm2.
Power supply cable connection
External terminal board 6+1 poli
Unscrew the fixing screw (1) of the terminal
board cover box (see picture above)
- Take the terminal board box off
- Take the mobile part of the cable press
lation and side by side positioning.
With particular reference to the ovens, all
models must be placed upon a support, for
example a prover, a stand or a metal table.
Do not ever install the appliance on the floor.
If the appliance is placed near walls, dividers,
kitchen cabinets, decorated edges, etc., it is
recommended that this be of non combustible
material.
Otherwise, they must be coated with non com-
bustible thermal insulating material and you
must be very respectful of the fire prevention
standards.
3.4 Remove the protective film
Carefully remove all the protective film from the
external walls of the appliance. Pay attention
not to leave any rest of glue on the sides.
If there should be any residue, please remove
it with an appropriate solvent.
4. INSTALLATION
4.1 – ELECTRICAL CONNECTION
4.2 – WATER CONNECTION
4.1 Electrical connection
a-The connection to the electrical power
supply system must be done according to
the standard in force.
Before connecting the appliance, make
yourself sure that the voltage and the fre-
quency correspond to those stated on the
data plate of the appliance. The appliance
must be placed so that the connection plug
to the network can be easily reached.
Place an omni-polar switch between the
appliance and the network so that it is easily
accessible. The contacts of this switch must
have a minimum opening distance of 3
mm and the switch must have an appro-
priate input (for example, magneto-thermal
switch).
When the appliance is working the power
supply voltage must not diverge from the
value of the nominal voltage, written on the
technical data plate, by more than ± 10%.
ENGLISH
3
ENGLISH
Summary of Contents for BakerLux XB
Page 15: ...14 ENGLISH ENGLISH ...
Page 16: ...ENGLISH 15 ENGLISH APPENDIX 1 ...
Page 17: ...ENGLISH 16 ENGLISH APPENDIX 2 ...
Page 31: ...FRANCAIS 14 FRANCAIS ...
Page 32: ...FRANCAIS 15 FRANCAIS APPENDICE 1 ...
Page 33: ...FRANCAIS 16 FRANCAIS APPENDICE 2 ...
Page 47: ...DEUTSCH 14 DEUTSCH ...
Page 48: ...DEUTSCH 15 DEUTSCH ANHANG 1 ...
Page 49: ...DEUTSCH 16 DEUTSCH ANHANG 2 ...
Page 63: ...ITALIANO 14 ITALIANO ...
Page 64: ...ITALIANO ITALIANO APPENDICE 1 ...
Page 65: ...ITALIANO ITALIANO APPENDICE 2 ...
Page 79: ...ESPAÑOL 14 ESPAÑOL ...
Page 80: ...ESPAÑOL 15 ESPAÑOL APÉNDICE 1 ...
Page 81: ...ESPAÑOL 16 ESPAÑOL APÉNDICE 2 ...