Steel Body, Automatic Wood Pellet Feed Hot Water Boiler Operation and Maintenance
Manual
SAFETY WARNINGS
The boiler must be connected to a chimney in accordance with the specifications specified in the
operating instructions and the relevant regulations. The flue must provide the required traction value
of the connected boiler. Your boiler should not be operated without chimney connection and there
should be sufficient traction for combustion. In chimneys with insufficient traction, the boiler should
never be operated. Any improper electrical installation in the place where the boiler is installed
should be removed.
In case of a boiler change in boiler rooms, the old boiler should be removed or the connection to the
chimney should be cut and the cut-off place should be sealed and insulated. In no case should more
than one boiler be connected to the same chimney.
Smoke chimneys should not be placed on the exterior wall of the building unless it is a technical
requirement. The wall thickness of the chimney walls should not be less than the thickness of a brick.
Perforated bricks and briquettes should never be used in chimney construction. It must be plastered
from inside and outside and the cylindrical pipe is inserted into the rectangular chimney.
Fresh air must be provided to the area where the boiler is installed. The dimensions specified in this
manual should be referenced. The boiler should in no way be installed in a place directly connected
to the living spaces or to such a place. To reduce the risk of calcification and corrosion in old and new
installations, the instructions given in the relevant section of this manual must be followed by the
installer of the boiler. In particular, if the boiler is connected to an old installation, the installation
must be flushed several times to completely remove any waste from the installation before
installation.
Avoid overloading the boiler, never open the cover and do not feed manually into the burner. The
operating and stopping times of the gear unit are entered into the boiler as a program. These
settings are related to the chimney characteristics of the boiler (traction difference, etc.), ambient
conditions, thermal comfort requirement of the space, insulation of the space, etc. it depends on
many parameters.
WARNING
This product must be connected to the mains by grounding!
WARNING
The electrical installation of this product must be carried out by authorized personnel
in accordance with the descriptions given in this manual and the applicable local or
national regulations.