Gas burning pizza brickoven
R-001 100518
Page 18 of 33
It is the electrician's responsibility to size and install the oven's supply cable to the mains
system according to the oven's electrical specifications (see data on the plate).
All wiring should conform the Local codes and NEC.
The appliance must be electrically grounded in accordance with the local
codes, or in absence of local codes, with the National Electrical Code
NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
The oven is equipped with a connection box, with terminal block inside,
located on front, right side, pre-drilled to receive a 1/2" conduit.
Install the conduit and proceed driving a proper branch circuit wire in the
conduit from the electrical panel to the connection box.
Loosen the upper screws of the field wire terminal.
Insert the bare wire ends in the field wire terminal openings according to
the scheme (fig 7.1) and tighten the screws securely.
NOTE: Electrical diagrams are located inside the connection box, shown below
Fig 7.1.1
Connection Box Highlighted view
7.3.1 Electrical specifications
Voltage
120/240 2W
Frequency
50-60Hz
Amp
16