Universal Tool UT8862 Operating Instructions Download Page 1

Description

The Universal Tool Superhand Air File is designed to file small areas with restricted

access with ease.  This reciprocating air file weighs just over two pounds for easy

one-handed operation.  Features include a hanging bail for easier handling, a

thumb switch throttle for easy start-up, and a durable steel housing.  Able to file

steel, plastic, wood and aluminum.  It’s 1/4” stroke length makes quick work of most

jobs.  Includes 4 assorted files: flat, round, triangular and bastard cut.

UT8862

SUPERHAND AIR FILE

PLEASE READ AND FOLLOW ALL WARNINGS

Read Operating Instructions

Always become familiar with all the

instructions and warnings before

operating any power tool.

Always Wear Approved

Eye Protection

Impact resistant eye protection

should meet or exceed the

standards as set forth in the United

States ANSI Z87.1, Occupational

and Educational Eye and Face

Protection. Look for the marking

Z87.1 on your eye protection to

insure that it is an approved style.

For further information, ANSI Z87.1,

Occupational and Educational Eye

and Face Protection, is available

from the American National

Standards Institute, Inc., 11 West

42nd Street, New York, NY 10036.

Hearing Protection is

Recommended

Hearing protection should be used

when the noise level exposure

equals or exceeds an 8 hour time-

weighted average sound level of 85

dBA. Process noise, reflective

surfaces, other tools being

operated nearby, all add to the

noise level present in your work

area. If you are unable to determine

your noise level exposure, we

recommend the use of hearing

protection.

Avoid Prolonged Exposure to

Vibration

Tools can vibrate during use.

Prolonged exposure to vibration or

very repetitive hand and arm

movements, can cause injury.  Stop

using any tool if discomfort, tingling

feeling or pain occurs.  You should

consult your physician before

resuming use of the tool.

90 PSIG Maximum

This tool is designed to operate at

an air pressure of 90 pounds per

square inch gauge pressure (90

PSIG) maximum, at the tool. Use of

higher air pressure can, and may

cause injury.  Also, the use of

higher air pressure places the

internal components under loads

and stresses they were not

designed for, causing premature

failure. The air supply should be

clean and dry, preferably

lubricated. For best results, drain

the moisture from your compressor

daily.

PL-0258

Universal Tool

A Division of Florida Pneumatic Manufacturing Corporation

851 Jupiter Park Lane, Jupiter, Florida 33458

Toll Free 1-800-327-9403

Read these instructions carefully before attempting to install, operate

or service this Florida Pneumatic product.  Failure to comply with the

instructions could result in personal injury and/or property damage!

Retain these instructions for future reference.

Safety Instructions

The following instructions are furnished

as general guidelines for use of your

pneumatic tool.  They cannot compre-

hensively cover all possible or conceiv-

able uses of the subject tool.  For

additional information on the safe use

of air tools, we advise you to obtain a

copy of ANSI B186.1 Safety Code for

Portable Air Tools, available from the

following source:

American National Standards

Institute, Inc.

11 West 42nd Street

New York, NY 10036.

The use of the word “shall” in the

following instructions, indicates that

adherence to the particular require-

ment is necessary to conform to ANSI

B186.1.

Tool Application and Usage

Portable tools shall be used only for

the purposes intended in their design

and within the capacity for which they

were intended and rated.  It shall be

the tool owner’s and/or employer’s

responsibility to instruct each operator

in the safe use of the tool.  Tools shall

not be used without guards and safety

devices as furnished by the manufac-

turer.  Where an air tool is modified or

altered, the modifier shall provide the

safeguards to enable it to be safely used

in the operations intended and to comply

with any applicable provisions as

contained in ANSI B186.1.

Tool Installation

Pressure regulators shall be used to limit

air pressure to the rated pressure where

the supply pressure exceeds the tool’s

rated pressure.  Air hoses and lines shall

be relieved of compressed air before

being disconnected or disjointed, unless

there is automatic valve closing protec-

tion at the joint being separated.  Syn-

thetic lubricants which can cause

deterioration of elastomer seals shall not

be used in air systems of air tools.

Tool Maintenance

It shall be the tool owner’s and/or

employer’s responsibility to assure that

tools are maintained in a safe operating

condition.  Tool maintenance and repair

shall be performed by authorized,

trained, competent personnel.  Tools shall

be disconnected from their compressed

air supply before repairs are attempted.

Repairs shall be consistent with the

manufacturer’s recommended proce-

dures.  Tool, hoses and fittings shall be

replaced if unsuitable for safe operation.

It shall be the tool owner’s and/or

employer’s responsibility to keep required

rating markings and warnings on the tool

in legible condition.

FPMC

Rev. 8/98

WARNING:

Some dust created by power sanding, sawing,

grinding, drilling, and other construction activities

contains chemicals known to cause cancer, birth

defects or reproductive harm. Some examples

of these chemicals are:

Lead from lead-based paints

Crystalline silica from bricks, cement and

other masonry products

Arsenic and chromium from chemically

treated lumber

Your risk from these exposures varies,

depending on how often you do this type of

work. To reduce your exposure to these

chemicals, work in a well-ventilated area and

work with approved safety equipment such as

those dust masks that are specially designed to

filter out microscopic particles.

Reviews: