background image

 

 FLORIDA-PNEUMATIC.COM 

 

Please contact 1-800-356-3392 for further assistance.

Universal Tool

4 Bolt Chipping Hammers

General Safety Information & Replacement Parts

WARNING:

 Risk of injury to persons. Read and 

understand operation instructions.  Always become familiar 
with all the instructions and warnings before operating any 
pneumatic tool.

TABLE OF CONTENTS

General Safety Information    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2 
Air Compressor and Air Tool Safety  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2-3 
Tool Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3-4
Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Maintenance / Lubrication   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Troubleshooting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Warranty   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Service Parts  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7 

UT8651R / UT8651H 

1" Stroke Chipping Hammers

UT8651R / UT8651H
UT8652R / UT8652H 
UT8653R / UT8653H 
UT8654R / UT8654H 

UT8652R / UT8652H 

2" Stroke Chipping Hammers

UT8653R / UT8653H 

3" Stroke Chipping Hammers

UT8654R / UT8654H 

4" Stroke Chipping Hammers

WARNING

:

 This product contains chemicals known to 

the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

WARNING

:

 This product contains lead, a chemical known to 

the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

Summary of Contents for UT8651R

Page 1: ...allation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 UT8651R UT8651H 1 Stroke Chipping Hammers UT8651R UT8651H UT8652R UT8652H UT8653R UT8653H UT8654R UT8654H UT8652R UT8652H 2 Stroke Chipping Hammers UT8653R UT8653H 3 Stroke Chipping Hammers UT8654R UT8654H 4 Stroke Chipping Hammers WARNING This product contains chemicals known to the State of California t...

Page 2: ... used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis risk assessment of these hazards and implementation of appropriate controls of is essential Risk assessment should include dust created by the use of the tool and the potential for disturbing existing...

Page 3: ...ted for use only in non rotary percussive power tools 5 For hammers and breakers where appropriate never use blunt chisels as they require excessive pressure and can break from failure Blunt tool pieces can increase vibration and therefore sharp tools should always be used 6 Avoid direct contact with the inserted tool during and after use as it can be hot or sharp 7 Never adjust the non rotary per...

Page 4: ... in sustained operation Regularly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holding the throttle open approximately 30 seconds The lubricator is properly set when a light stain of oil collects on the paper If it is necessary to store the tool for an exte...

Page 5: ...operly held by the retainer spring before use 3 Removing the chisel Rotate the spring counterclockwise to remove the retainer spring A Pull the chisel out of the air hammer B WARNING Do not operate the tool without the chisel in cylinder or allow the chisel to be driven out of the cylinder Internal damage will result if the piston strikes the cylinder wall 4 Operating the air hammer Push WARNING D...

Page 6: ... cost or expense of repair or replacement as described above Troubleshooting Problem Possible Cause Solution The tool runs slowly or will not operate There is grit or gum in the tool Flush the tool with air tool oil or gum solvent The tool is out of oil Lubricate the tool according to the lubrication instructions in this manual The air pressure is low Adjust the regulator on the tool to the maximu...

Page 7: ... FLORIDA PNEUMATIC COM Please contact 1 800 356 3392 for further assistance Service Parts Exploded View Drawing ...

Page 8: ...umatic Manufacturing Corporation 851 Jupiter Park Lane Jupiter FL 33458 Universal Tool Questions problems missing parts Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 FLORIDA PNEUMATIC COM Retain this manual for future use ...

Reviews: