Specifications

 

Frequency:

  

 

 

2.4

 

GHz

 

(IEEE

 

802.15.4)

 

Operating

 

Temperature:

  

32°

113°F

 

(0°

45°C)

 

Operating

 

Humidity:

   

85%

 

RH

 

non

condensing

 

Battery:

  

 

 

1x

 

CR123A

 

Panasonic

 

Lithium

 

3V

 

DC

 

Battery

 

Life:

    

 

3

 

Years

 

Compatibility:

    

 

Zigbee,

  

WWAH

 

(Works

 

with

 

All

 

Hubs)

 

Pet

 

Immunity:

    

 

Up

 

to

 

50

 

lbs

 

Coverage

 

Area:

  

 

40

 

feet

 

by

 

40

 

feet,

 

90°

 

angle

 

Light

 

Immunity:

  

 

1500

 

Lux

 

Coverage

 

Pattern:

 

 

 

Side

 

View:

       

 

 

 

 

Top

 

View:

 

 

      

 

 

 

2.

 

Package

 

Contents

 

1x

 

Sensor

   

 

 

4x

 

Screws

 

&

 

Wall

 

Anchor

 

1x

 

CR123A

 

battery

 

(installed)

 

2x

 

Sensor

 

Case

 

Screw

 

1x

 

Back

 

Mounting

 

2

Sided

 

Adhesive

 

Tape

 

1x

 

Manual

   

 

2x

 

Side

 

Mounting

 

2

Sided

 

Adhesive

 

Tape

 

 

 

 

3.

 

Component

 

Identification

 

 

    

 

 

4.

 

Zigbee

 

Enrollment:

 

This

 

PIR

 

Motion

 

Sensor

 

needs

 

to

 

be

 

paired

 

before

 

installation.

 

1.

 

Pull

 

the

 

exposed

 

plastic

 

battery

 

tab.

 

2.

 

The

 

LED

 

will

 

blink

 

three

 

times

 

every

 

2

3

 

seconds

 

in

 

amber

 

color

 

while

 

scanning

 

the

 

network.

 

3.

 

If

 

network

 

is

 

found

 

and

 

successfully

 

joined,

 

the

 

LED

 

will

 

be

 

lit

 

for

 

1

 

second

 

in

 

amber

 

color

 

followed

 

by

 

a

 

short

 

blink

 

in

 

green

 

color.

 

4.

 

If

 

network

 

is

 

not

 

found

 

after

 

1

 

minute,

 

the

 

sensor

 

will

 

go

 

into

 

sleep

 

mode

 

and

 

the

 

LED

 

will

 

blink

 

in

 

amber

 

color

 

every

 

1

 

minute.

 

You

 

need

 

to

 

reset

 

the

 

sensor

 

to

 

trigger

 

a

 

pairing

 

process,

 

and

 

then

 

sensor

 

will

 

repeat

 

steps

 

from

 

2

 

to

 

4.

 

To

 

reset

 

the

 

sensor:

 

1.

 

Remove

 

the

 

battery

 

for

 

10

 

seconds

 

2.

 

Press

 

and

 

hold

 

down

 

the

 

temper

 

switch

 

while

 

re

insert

 

the

 

battery

 

3.

 

Release

 

the

 

temper

 

switch

 

within

 

3

 

seconds

 

 

 

5.

 

Mounting

 

 

Mount

 

the

 

PIR

 

Motion

 

Sensor

 

at

 

7.5

 

feet

 

(2.3

 

meters)

 

above

 

the

 

floor.

  

 

Press

 

the

 

case

 

release

 

button

 

to

 

separate

 

the

 

front

 

and

 

back

 

sensor

 

case.

  

 

The

 

back

 

case

 

gives

 

access

 

to

 

both

 

the

 

flush

 

mount

 

and

 

corner

 

mount

 

screw

 

knock

 

outs.

 

Drill

 

through

 

the

 

appropriate

 

knockouts

 

and

 

use

 

the

 

included

 

screws

 

to

 

mount

 

in

 

the

 

desired

 

mounting

 

location.

  

 

It

 

is

 

recommended

 

to

 

ensure

 

there

 

is

 

a

 

tight

 

seal

 

around

 

the

 

knockouts

 

to

 

prevent

 

bugs

 

from

 

entering

 

the

 

sensor

 

and

 

causing

 

false

 

alarms.

  

 

Replace

 

the

 

front

 

sensor

 

cover

 

to

 

snap

 

shut

 

and

 

screw

 

in

 

the

 

sensor

 

case

 

screws

 

on

 

the

 

top

 

and

 

bottom

 

of

 

the

 

back

 

sensor

 

case.

  

 

6.

 

Walk

 

Test

 

Mode

 

Walk

 

test

 

mode

 

can

 

be

 

used

 

to

 

test

 

the

 

motion

 

sensor

 

detection

 

coverage

 

area.

 

To

 

enter

 

walk

test

 

mode:

 

1.

 

Remove

 

the

 

battery

 

for

 

10

 

seconds

 

2.

 

Press

 

and

 

hold

 

down

 

the

 

tamper

 

button

 

while

 

re

insert

 

the

 

battery

 

3.

 

Keep

 

the

 

tamper

 

switch

 

hold

 

down

 

for

 

10

 

seconds

 

then

 

release

 

The

 

LED

 

will

 

begin

 

to

 

blink

 

slowly

 

in

 

amber

 

to

 

indicates

 

the

 

motion

 

sensor

 

is

 

warming

 

up.

 

After

 

45

 

seconds,

 

the

 

LED

 

will

 

stop

 

blinking

 

which

 

indicates

 

the

 

motion

 

sensor

 

is

 

ready

 

to

 

detect

 

motion.

 

The

 

LED

 

will

 

be

 

lit

 

in

 

red

 

color

 

to

 

illuminate

 

each

 

time

 

motion

 

is

 

detected.

 

Once

 

the

 

LED

 

goes

 

out,

 

the

 

sensor

 

is

 

ready

 

to

 

detect

 

motion

 

again.

 

Walk

 

test

 

mode

 

ends

 

after

 

20

 

motions

 

detected,

 

or

 

no

 

motion

 

detected

 

for

 

1

 

minutes.

 

It

 

is

 

recommended

 

that

 

the

 

PIRZB2

ECO

 

is

 

tested

 

monthly

 

to

 

ensure

 

proper

 

function.

 

 

7.

 

Operation

 

The

 

PIR

 

Motion

 

Sensor

 

requires

 

45

 

seconds

 

to

 

warm

 

up

 

for

 

signal

 

stabilizing

 

when

 

performing

 

start

 

up

 

or

 

reset.

 

During

 

the

 

warmup

 

period,

 

the

 

LED

 

will

 

blink

 

slowly

 

in

 

amber.

  

After

 

warmup

 

completed,

 

the

 

LED

 

will

 

blink

 

every

 

5

 

minutes

 

in

 

green

 

color

 

to

 

indicate

 

the

 

sensor

 

is

 

working

 

properly.

 

However,

 

there

 

are

 

no

 

LED

 

indications

 

when

 

motion

 

is

 

detected.

 

This

 

is

 

done

 

to

 

maximize

 

battery

 

life.

 

Furthermore,

 

when

 

motion

 

is

 

detected

 

and

 

a

 

signal

 

is

 

transmitted

 

to

 

the

 

panel,

 

the

 

sensor

 

will

 

not

 

transmit

 

again

 

until

 

there

 

are

 

no

 

motion

 

detected

 

for

 

a

 

period

 

of

 

3

 

minutes

 

and

 

motion

 

is

 

detected

 

again.

 

 

8.

 

Maintenance

 ‐ 

Replacing

 

the

 

Battery

 

When

 

the

 

battery

 

is

 

low,

 

a

 

signal

 

will

 

be

 

sent

 

to

 

the

 

control

 

panel.

 

The

 

LED

 

will

 

blink

 

every

 

2

 

minutes

 

in

 

red

.

 

To

 

insert

 

or

 

replace

 

the

 

battery:

 

1.

 

Press

 

the

 

case

 

release

 

button

 

to

 

separate

 

the

 

front

 

and

 

back

 

sensor

 

case

 

2.

 

Remove

 

the

 

front

 

case

 

to

 

expose

 

the

 

battery

 

3.

 

Replace

 

the

 

CR123A

 

lithium

 

battery.

 

Note

 

the

 

correct

 

orientation

 

of

 

the

 

battery

 

as

 

shown

 

on

 

the

 

battery

 

compartment.

 

4.

 

Replace

 

the

 

front

 

cover.

 

 

WARNING:

 

Failure

 

to

 

follow

 

these

 

warnings

 

and

 

instructions

 

can

 

lead

 

to

 

heat

 

generation,

 

rupture,

 

leakage,

 

explosion,

 

fire,

 

or

 

other

 

injury,

 

or

 

damage.

 

Do

 

not

 

insert

 

the

 

battery

 

into

 

the

 

compartment

 

in

 

the

 

wrong

 

direction.

 

Always

 

replace

 

the

 

battery

 

with

 

the

 

same

 

or

 

equivalent

 

type

 

(see

 

Specifications

 

on

 

section

 

1).

 

Never

 

recharge

 

or

 

disassemble

 

the

 

battery.

 

Never

 

place

 

the

 

battery

 

in

 

fire

 

or

 

water.

 

Always

 

keep

 

batteries

 

away

 

from

 

small

 

children.

 

If

 

batteries

 

are

 

swallowed,

 

promptly

 

see

 

a

 

doctor.

 

 

Always

 

dispose

 

and/or

 

recycle

 

used

 

batteries

 

in

 

accordance

 

with

 

the

 

hazardous

 

waste

 

recovery

 

and

 

recycling

 

regulations

 

for

 

your

 

location.

 

Your

 

city,

 

state,

 

or

 

country

 

may

 

also

 

require

 

you

 

to

 

comply

 

with

 

additional

 

handling,

 

recycling,

 

and

 

disposal

 

requirements.

 

 

 

 

7.5 ft

0

       

3

        

6

      

10

    

13

     

16

    

19

     

23

     

26

     

29

     

33

    

36

    

40

 

 

 

 

      

(feet)

 

         

29

  

26

 

23

 

19

 

16

 

13

  

9

   

6

   

3

   

0

   

3

   

6

   

9

  

13

 

16

  

19

 

23

 

26

  

29

 

0

       

3

        

6

      

10

    

13

     

16

    

19

     

23

     

26

     

29

     

33

    

36

    

40

 

0
3
6

10
13
16
19
23
26
29
33
36
40

 

Tamper

 

Switch

 

CR123A

 

Battery

 

Case

 

Release

 

Button

 

Sensor

 

Case

 

Screws

 

 

 

 

      

(feet)

 

(feet)

 

Reviews: