background image

UNIVERSAL AUDIO Model 175 B LIMITING AMPLIFIER 

 

 

 

BALANCING ADJUSTMENTS 

Inherent  stability  eliminates  the  need  for  frequent  balancing  of  the  175  B. 
However, if thumping is noticed or components are replaced, the unit should be 
balanced as follows: 

a.

 

If using TEST 1 position, remove any input signal from the amplifier. 
 

b.

 

Set the attack and release controls to approximate mid settings. 
 

c.

 

Rotate  the  input  and  output  attenuators  fully  counter  clockwise 
(maximum attenuation). 
 

d.

 

Set the meter switch to OUTPUT position. 
 

e.

 

Set test switch to TEST 1 position. 
 
NOTE: If desired, balanced can be performed by applying a 3-volt external 
signal to the input jacks and setting the test switch to TEST 2 position. 
 

f.

 

Rotate the output attenuator clockwise until an indication is observed on 
the meter. 
 

g.

 

Adjust  first  the  PLATE  BALANCE  and  then  the  CATHODE  BALANCE 
controls for minimum meter deflection. 
 

h.

 

Rotate the output attenuator fully clockwise (zero attenuation). 
 

i.

 

Adjust  first  the  PLATE  BALANCE  and  then  the  CATHODE  BALANCE 
controls for minimum meter deflection. Note meter indication. 
 

j.

 

Adjust the PLATE BALANCE control slightly clockwise until a change in 
meter  indication  is  observed.  Then  attempt  to  adjust  CATHODE 
BALANCE control for meter indication less than noted in step i. 
 

1)

 

If meter indication is less than that noted in  step i, perform step j 
repeatedly until absolute minimum meter indication is obtained. 
 

2)

 

If meter indication is not less than that noted in step i, adjust the 
PLATE BALANCE control slightly counter clockwise until a change 
in  the  meter  indication  is  observed.  Then  adjust  the  CATHODE 
BALANCE  control  for  minimum  deflection.  Perform  sub-setup  (2) 
repeatedly until absolute minimum meter deflection is obtained. 

Summary of Contents for 175 B

Page 1: ... FP electrolytic capacitors are used for ease of replacement The 175 B has a self contained power supply a VU meter that is switchable to indicate input or output level as well as gain reduction in dB and input and output attenuators graduated in 2 dB steps with vernier adjustments in excess of 2dB for each step The limiter is provided with input and output jacks on the front panel as well as a te...

Page 2: ...gram allows the remote VU meter to perform gain reduction while the internal meter is still usable to indicate input and output level ATTENUATORS The input and output attenuators are both adjustable from 0 to 40 dB For this reason the 175 B may be utilised at any point in the system where input signal level is between 24 dBm and 13 dBm The attenuators are adjusted for proper operating levels as fo...

Page 3: ...erial being used The following general suggestions are given for use of ATTACK and RELEASE adjustments a For vocal or narration program material with minimum low frequency information best results are usually obtained by adjusting for very fast attack and release times b The release time should be lengthened as the low frequency content of the program material increase c The attack time should be ...

Page 4: ... observed on the meter g Adjust first the PLATE BALANCE and then the CATHODE BALANCE controls for minimum meter deflection h Rotate the output attenuator fully clockwise zero attenuation i Adjust first the PLATE BALANCE and then the CATHODE BALANCE controls for minimum meter deflection Note meter indication j Adjust the PLATE BALANCE control slightly clockwise until a change in meter indication is...

Page 5: ...e absolute minimum meter deflection should be in the order of 20 dB If the two sections of the 6BC8 are not reasonably symmetrical optimum balancing cannot be obtained NOTE The fastest attack or release time is attained by turning the control full clockwise ...

Page 6: ...er in high gain position 37 dB MINIMUM INPUT LEVEL TO ACCOMPLISH LIMITING Jumper in low gain position 24 dBm Jumper in high gain position 24 dBm MAXIMUM OUTPUT AT THERSHOLD OF LIMITING 13 dBm INPUT AND OUTPUT IMPEDANCE 600 ohms unbalanced SIGNAL TO NOISE RATIO 80 dB COMPRESSION RATIO above threshold of limiting 12 to 1 ATTACK TIME Adjustable from 100 to 1000 microseconds REALEASE TIME Adjustable f...

Page 7: ...UNIVERSAL AUDIO Model 175 B LIMITING AMPLIFIER 7 ...

Reviews: