background image

Unitronics  

1

Vision™ OPLC™

 

V350-35-TA24  
Installation Guide

 

The Unitronics V350-35-TA24 offers the following onboard I/Os: 

12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC, and  
1 HSC/Shaft-encoder Input  
10 Transistor Outputs, 2 Analog Outputs 

General Description 

V350 OPLCs are micro-OPLCs, rugged programmable logic controllers that comprise:  

On-board I/O configuration 
Built-in operating panel containing a 3.5” Color Touchscreen and programmable function keys 

Communications 

1 built-in serial port: RS232/RS485  
Optional: the user may order and install 
one or both of the following modules:  
- RS232/RS485/Ethernet  
- CANbus  
Communication Function Blocks 
include: SMS, GPRS, MODBUS serial/IP. 
Protocol FB enables PLC to 
communicate with almost any external 
device, via serial or Ethernet 
communications 

I/O Options 

V350 supports digital, high-speed, analog, 
weight and temperature measurement I/Os via: 

On-board I/O configuration
Model-dependent 
I/O Expansion Modules
Local or remote I/Os may be added via 
expansion port or CANbus.  

Information Mode 

This mode enables you to: 

View & Edit operand values, COM port settings, RTC and screen 
contrast/brightness settings 
Calibrate the touchscreen 
Stop, initialize, and reset the PLC 

To enter Information Mode, press the <i> button for several seconds. 

Programming 
Software,  
& Utilities 

The Unitronics Setup CD contains VisiLogic software and other utilities 

VisiLogic
Easily configure hardware and write both HMI and Ladder control 
applications; the Function Block library simplifies complex tasks 
such as PID. Write your application, and then download it to the 
controller via the programming cable included in the kit. 
Utilities
Includes UniOPC server, Remote Access for remote programming 
and diagnostics, and DataXport for run-time data logging. 

To learn how to use and program the controller, as well as use utilities such as 
Remote Access, refer to the VisiLogic Help system. 

 

Summary of Contents for Vision OPLC V350-35-TA24

Page 1: ...d analog weight and temperature measurement I Os via On board I O configuration Model dependent I O Expansion Modules Local or remote I Os may be added via expansion port or CANbus Information Mode This mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Calibrate the touchscreen Stop initialize and reset the PLC To enter Information Mode pres...

Page 2: ...g this product the user must read and understand this document All examples and diagrams are intended to aid understanding and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry...

Page 3: ...ller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure ...

Page 4: ...5 kgf cm Do not use tin solder or any substance on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Wiring Procedure Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Ins...

Page 5: ... PT100 Input and Output Jumper Settings The tables below show how to set a specific jumper to change input functionality To access the I O jumpers you must open the controller according to the instructions beginning on page 10 Incompatible jumper settings and wiring connections may seriously damage the controller Digital Inputs 0 11 Set Type Set to JP12 all Inputs npn sink A pnp source B Inputs 7 ...

Page 6: ...24 Installation Guide 6 Unitronics I O Wiring I O Configuration npn Input Wiring Input wiring npn sink HSC input wiring npn sink pnp Input Wiring Input wiring pnp source HSC input wiring pnp source Shaft encoder ...

Page 7: ...Wire Color ANSI USA BS1843 UK mV 5 to 56mV B 200 to 1820PC 300 to 3276PF Grey Red None Blue E 200 to 750PC 328 to 1382PF Violet Red Brown Blue J 200 to 760PC 328 to 1400PF White Red Yellow Blue K 200 to 1250PC 328 to 2282PF Yellow Red Brown Blue N 200 to 1300PC 328 to 2372PF Orange Red Orange Blue R 0 to 1768PC 32 to 3214PF Black Red White Blue S 0 to 1768PC 32 to 3214PF Black Red White Blue T 200...

Page 8: ...wer supply Do not connect either the Neutral or Line signal of the 110 220VAC to device s 0V pin In the event of voltage fluctuations or non conformity to voltage power supply specifications connect the device to a regulated power supply Earthing the Power Supply To maximize system performance avoid electromagnetic interference by Mounting the controller on a metal panel Earthing the controller s ...

Page 9: ...ve the RS485 connector and connect the PC to the PLC via the programming cable Note that this is possible only if flow control signals are not used which is the standard case RS232 RS485 Controller Port Pin Description Pin Description 1 DTR signal 1 A signal 2 0V reference 2 RS232 signal 3 TXD signal 3 RS232 signal 4 RXD signal 4 RS232 signal 5 0V reference 5 RS232 signal 6 DSR signal 6 B signal P...

Page 10: ... must replace the back cover securely before powering up the controller The information in this document reflects products at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily ...

Reviews: