background image

 

Unitronics 

 

 

Samba™ OPLC™ 

OPLC Installation Guide 

SM43-J-R20/SM35-J-R20 

12 Digital Inputs, include 1 HSC/Shaft-encoder Input,  
 2 Analog  inputs (only when the digital inputs are set to pnp),  
 8 Relay Outputs

 

SM43-J-T20/ SM35-J-T20 

12 Digital Inputs, include 3 HSC/Shaft-encoder Input,  
 2 Analog inputs, 8 Transistor Outputs

 

 

General Description 

The SAMBA SM43-J-R20/SM43-J-T20 OPLC is an All-in-One Programmable Logic Controller that  
Comprises a built-in 4.3" Color Touchscreen. 
The SAMBA SM35-J-R20/SM35-J-T20 OPLC is an All-in-One Programmable Logic Controller that  
Comprises a built-in 3.5" Color Touchscreen. 

Communications 

  For SM43: USB device programming port (Mini-B) 

For SM35:  1 build-in serial port:RS232 

  Optional: the user may install -  

RS232/RS485 port (V100-17-RS4/V100-17-RS4X) or Ethernet (V100-17-ET2)   
& CANbus (V100-17-CAN) 

 

Standard Kit Contents 

Samba controller 

Mounting brackets (x2) 

I/O connectors (x2) 

Rubber seal 

Battery (installed) 

 

Alert Symbols and General Restrictions 

When any of the following symbols appear, read the associated information carefully. 

Symbol 

Meaning 

Description 

 

Danger 

The identified danger causes physical and property damage. 

 

Warning 

The identified danger could cause physical and property damage. 

Caution

 

Caution 

Use caution. 

 

Before using this product, the user must read and understand this document.  

 

All examples and diagrams are intended to aid understanding, and do not guarantee operation. 
Unitronics accepts no responsibility for actual use of this product based on these examples. 

 

Please dispose of this product according to local and national standards and regulations. 

 

Only qualified service personnel should open this device or carry out repairs. 

  Failure to comply with appropriate safety guidelines can cause severe injury or property damage. 

 

 

Do not attempt to use this device with parameters that exceed permissible levels. 

 

To avoid damaging the system, do not connect/disconnect the device when power is on. 

Environmental Considerations 

 

 

Do not install in areas with: excessive or conductive dust, corrosive or flammable gas,  
moisture or rain, excessive heat, regular impact shocks or excessive vibration, in  
accordance with the standards given in the product’s technical specification sheet. 

 

Do not place in water or let water leak onto the unit. 

 

Do not allow debris to fall inside the unit during installation. 

 

 

Ventilation: 10mm space required between controller’s top/bottom edges & enclosure walls. 

 

Install at maximum distance from high-voltage cables and power equipment. 

 

Чтобы

 

подобрать

 

подходящую

 

модель

уточнить

 

стоимость

 

и

 

срок

 

поставки

 

обращайтесь

 

к

 

нашим

 

специалистам

 

по

 

электронной

 

почте

 [email protected] 

или

 

по

 

телефонам

 +7(499)707-11-20 +7(499)707 11 30, 

8-800-511-65-88 (

Бесплатно

 

по

 

России

)

Summary of Contents for Samba OPLC SM35-J-R20

Page 1: ...his product the user must read and understand this document All examples and diagrams are intended to aid understanding and do not guarantee operation Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry ou...

Page 2: ...Samba OPLC Installation Guide 2 Unitronics Mounting Dimensions SM43 J R20 SM43 J T20 SM35 J R20 SM35 J T20 ...

Page 3: ...ace 3 Push the mounting brackets into their slots on the sides of the panel as shown in the figure to the right 4 Tighten the bracket s screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure to the right Note For UL listed module in order to meet the UL508...

Page 4: ...s squarely situated in the panel cut out as shown in the figure to the right Note For UL listed module in order to meet the UL508 standard panel mount this device on the flat surface of a Type 1 enclosure Wiring Do not touch live wires Install an external circuit breaker Guard against short circuiting in external wiring Use appropriate circuit protection devices Unused pins should not be connected...

Page 5: ...ropriate wiring Inputs 5 and 6 can function as either digital or analog inputs If the digital inputs function as npn analog option is not available Input 0 can function as a high speed counter as part of a shaft encoder or as a normal digital input Input 1 can function as either a counter reset normal digital input or as part of a shaft encoder If input 0 is set as a high speed counter without res...

Page 6: ...l Inputs 0 11 Set Type Set to JP12 all Inputs npn sink A pnp source B Input 5 Set Type Digital or Analog 1 Set to JP4 JP10 Digital A A Voltage B A Current B B Input 6 Set Type Digital or Analog 0 Set to JP8 JP9 Digital A A Voltage B A Current B B Default settings SM43 J T20 SM35 J T20 Do not move JP2 Digital Inputs 0 11 Set Type Set to JP1 all Inputs npn sink A pnp source B Inputs 10 11 Set as Dig...

Page 7: ...ler 2 The back cover of the controller comprises 4 screws located in the corners Remove the screws and pull off the back cover Changing I O Settings 1 The I O board of the controller is now exposed enabling you to change I O settings according to the jumpers above Closing the Controller 1 Replace the back cover of the controller and fasten the corner screws Note that you must replace the back cove...

Page 8: ...Samba OPLC Installation Guide 8 Unitronics HSC input wiring npn sink pnp Input Wiring SM43 J R20 SM35 J R20 SM43 J T20 SM35 J T20 Input wiring pnp source HSC input wiring pnp source ...

Page 9: ... J T20 Analog Input Wiring SM43 J R20 SM35 J R20 SM43 J T20 SM35 J T20 Analog input wiring current 2 3 wire Analog input wiring current voltage 4 wire Shields should be connected at the signal s source The 0V signal of the analog input must be connected to the controller s 0V ...

Page 10: ...al 24VDC power supply Note Photo is for illustration purposes only 1 The power supply must include double insulation Outputs must be rated as SELV PELV Class 2 Limited Power 2 Use separate wires to connect the functional earth line pin 3 and the 0V line pin 2 to the system earth ground 3 Install an external circuit breaker Guard against short circuiting in external wiring 4 Double check all wiring...

Page 11: ...programming OS download and PC access SM35 J R20 SM35 J T20 This series comprises a build in RS232 port Caution Signals are related to the controller s 0V the same 0V is used by the power supply The serial port is not isolated If the controller is used with a non isolated external device avoid potential voltage that exceeds 10V Use RS232 to download programs from a PC and to communicate with seria...

Page 12: ...бург тел 7 343 287 19 19 yekaterinburg klinkmann spb ru Санкт Петербург тел 7 812 327 3752 klinkmann klinkmann spb ru Rīga tel 371 6738 1617 klinkmann klinkmann lv Helsinki puh 358 9 540 4940 automation klinkmann fi Tallinn tel 372 668 4500 klinkmann est klinkmann ee Vilnius tel 370 5 215 1646 post klinkmann lt Минск тел 375 17 2000 876 minsk klinkmann com www klinkmann ru sm35 j r20_en_1215 ...

Reviews: