![Unitek BAMOCAR-PG-D3-700/400 Manual Download Page 37](http://html1.mh-extra.com/html/unitek/bamocar-pg-d3-700-400/bamocar-pg-d3-700-400_manual_4034730037.webp)
Control connections
Edition: 2020 / V4
Page: 36
BAMOCAR-PG-D3-700/400-400
4.3
Digital outputs (open emitter)
Note: 12 V variant only on request
Output
Connector
Function
State
Parameter
BTB/RDY
X1:A
X1:B
Ready for operation
fixed /
solid state relais
DOUT1
X1:N
Digital output 1
programmable
DOUT2
X1:O
Digital output 2
programmable
DOUT3
X1:S
Digital output 3
programmable
DOUT4 (Option)
X11
Brake (option) 4
programmable
The auxiliary voltage is also the supply voltage for the logic outputs.
+12 to + 24 V for logic and auxiliary
voltage
Note total current of all outputs
GNDE logic ground
Output voltage
Level ON
+12.. +24 V=
Level OFF
< 1 V=
Output current
nom
1 A
Output current
max.
2 A, 1s
Voltage reference
+24 V
(X1:D)
Ground reference
GNDE
(X1:K)