![Unitek BAMOCAR-PG-D3-700/400 Manual Download Page 29](http://html1.mh-extra.com/html/unitek/bamocar-pg-d3-700-400/bamocar-pg-d3-700-400_manual_4034730029.webp)
Electrical installation
Edition: 2020 / V4
Page: 28
BAMOCAR-PG-D3-700/400-400
3.5
Connectors
Connectors are not included in delivery
Membrane
X9
CAN
X1
Control
X10
RS232
X7
Feedback Monitor
Ventil
BUS
In-Output
Parameter Sensor
Status-error
Connector X9
CAN
1
PE
2
Supply IN
3
CAN GND
4
CAN H
5
CAN L
Connector X1
Control inputs/outputs
A
brown
BTB
ready for operation
B
red
BTB
C
pink
GND24
auxiliary voltage 0
D
yellow
+24
auxiliary v
E
green
END1/LMT1
limit switch 1
F
blue
END2/LMT2
limit switch 2
G
violet
FRG/RUN
enable
H
grey
AIN1+
analog input 1
J
white
AIN1-
K
black
GNDE
logic zero
L
br-green
DIN1
digital input 1
M
br-yellow
DIN2
digital input 2
N
wh-green
DOUT1
digi-output 1
O
red-blue
DOUT2
digi-output 2
P
wh-yellow
AIN2+
analog input 2
R
wh-red
AIN2-
S
wh-grey
DOUT3
digi-output 3
T
wh-black
RFE
rotating field enable
U
wh-blue
+24V
auxiliary
Connector plug
connector female
Binder 99-5662-15-19