Electrical installation
Version: 2022 / V2
Page: 22
BAMOCAR-PG-D3-700-100/160
3
Electrical installation
3.1
Important advices
The order of the connections to the connector or terminal numbers is obligatory!
All further advice is non-obligatory. The input and output conductors may be altered or supplemented in
accordance with the electrical standards and guidelines.
Adhere to:
- connection and operating instructions
- local regulations
- EU guideline 2996/42/EC
- guidelines for vehicles ECE-R100, ISO 6469, ISO 26262
- VDE and TÜV regulations and Trade body guidelines
Electrical installation should only be carried out when all voltages have
been removed!
Ensure that the device is safely disconnected from the power supply
- place the short-circuit bracket
- affix warning signs
The installation should only be carried out by suitably trained personnel
for electrical engineering.
Compare the connection data with those indicated on the type plate.
Ensure that the correct fuses have been provided for the power supply and the auxiliary voltage.
Power supply conductors and control lines must be routed separately from each other.
Connection shields and grounding must be carried out in compliance with the EMC guidelines.
Use the correct line cross-sections.
Note:
Insert external isolation monitors!
•
Bad or insufficiently rated cable connections between the
battery and the device may cause damage to the device! (Brake
energy)
•
Power supply cables between the BAMOCAR and the battery
must be as short as possible. Long cables cause dynamic voltage
drops due to the line impedance and as a consequence the
service life of the installed capacitors would be reduced.