DATE
LOCATION INFORMATION
User
Address 1
Address 2
City, State, Zip
System
NITROGEN-PAC™ MODEL SC-W ASSEMBLY SERIAL NUMBER
TRUE ADVANCED PURGE™ #1 SERIAL NUMBER
TRUE ADVANCED PURGE™ #2 SERIAL NUMBER
MAINTENANCE – MODEL SC-W ASSEMBLY
STEP
MANUAL
REF.
PROCEDURE
OK
NOT
OK
1
Is the
GREEN
visual indicator on?
2
Has the manual particulate filter drain valve been opened, allowing any condensate to
drain, and the valve then been closed?
3
Is the SC nitrogen outlet hose present, secure and in good condition?
4
When the valves are positioned for system Fast Fill, is the bypass visual indicator
flashing
RED
?
See Quick Reference Valve Position Table.
5
Have the valves at the SC assembly been returned to the Nitrogen Generation
position per the Quick Reference Valve Position Table?
6
When the valves are positioned for Nitrogen Generation, does the bypass visual
indicator turn
OFF
? See Quick Reference Valve Position Table.
7
Is the drain connection connected to a hose or piping leading to a proper drain?
8
If present, is the condensate drain pump properly connected and in good working
order?
9
5.4.1
Has the compressor inlet filter been replaced?
10
5.4.2
Has the enclosure intake filter been replaced?
11
5.4.3
Has the exhaust fan filter element been replaced?
12
5.4.4
Have the filter elements in the coalescing and particulate filters been replaced?
13
5.4.4
Has the filter element in the water separator been replaced?
14
5.2.1
Has the nitrogen purity value at the Model SC-W assembly N
2
Purity Test Port
been checked and the Runtime Monitor value been checked and recorded below?
Model SC-W Assembly
N
2
Purity Test Port
Runtime Monitor
HRS
MIN
ANNUAL MAINTENANCE CHECKLIST
NITROGEN-PAC™ MODEL SC-W SYSTEM
UFS-624 REVISION 2.00 – PAGE 1 OF 4
APPENDIX E - SC-W MANUAL
Summary of Contents for Nitrogen Pac SC-W
Page 2: ... THIS SURFACE DELIBERATELY LEFT BLANK ...
Page 102: ...APPENDIX F SC W MANUAL ...
Page 103: ...APPENDIX F SC W MANUAL ...
Page 104: ...APPENDIX G SC W MANUAL ...