background image

-

6

-

Assembly Instructions

1.  Clean  the  fireplace  opening 

properly  disposing  of  any  ashes 

in a closed metal container. See 

Safety Instructions.

2.  Install  a  6”  (153  mm)  minimum 

diameter,  continuous  stainless 

steel  chimney  liner  into  the 

existing  chimney.  The  liner  must 

extend to the top of the existing 

chimney. Use only listed chimney 

liners  that  meet  UL  1777(US)  or 

ULC S635 (Canada).

3.  Remove  or  lock  the  fireplace 

damper  in  the  open  position. 

Note:  Masonry  or  damper 

plate  may  be  removed  to 

accommodate the chimney liner 

provided  this  does  not  weaken 

any  structural  components  of 

the existing fireplace or chimney 

nor reduces protection of 

combustible  materials  required 

by  national  building  codes. 

Consult with your local building or 

fire authority before doing this.

4.  Uncrate  the  appliance,  remove 

all  packing  materials,  and  any 

items stored in the firebox.

5.  WARNING:  Any  fireplace  which 

has  had  parts  removed  or 

modified  to  accommodate  the 

installation of this appliance 

MUST  have  a  warning  plate 

permanently installed in a visible location stating that the fireplace is unfit for use with solid fuel. This unit came 

with a metal warning label. Permanently attach the warning plate to a visible location in the fireplace. After 

choosing a visible location in the fireplace, permanently attach the warning plate by screwing or nailing it 

into place. Note: Use the holes in the label to mark and predrill the holes needed for attaching the label.

6.  Position the appliance into the fireplace opening until the top lip of the air jacket is flush with the fireplace 

facing.

7.  Level the appliance with the adjusting screws at the rear of the appliance.
8.  Connect the chimney liner to the appliance using a stainless steel adapter and securing with a minimum 

of three (3) sheet metal screws. The liner MUST be attached with the male (or crimped) end of the adapter 

inside the flue collar of the appliance to allow condensation and/or creosote to drain back into the firebox.

9.  Assemble the Surround. Lay pieces face down on carpet or other soft surface to protect finish during assembly. 

The Surround consists of two side panels, a top panel, and a decorative trim frame.

10.  Bolt the top panel (1) to the side panels (2 and 14) so the top surfaces are flush to one another using items 3 

and 4.

Masonry Fireplace

CAUTION:

 This appliance is heavy. Make sure that you have adequate help and use proper lifting techniques 

whenever moving this appliance.

Summary of Contents for VOGELZANG VG1820

Page 1: ...p in a safe place for future reference U S Environmental Protection Agency Certified to comply with 2020 particulate emissions standards CALIFORNIA PROPOSITION 65 WARNING This product can expose you t...

Page 2: ...a UL 103 HT U S Listed Residential Type and Building Heating Appliance Chimney Use a 6 diameter chimney that is high enough to create sufficient draft 11 Be sure your chimney is safely constructed and...

Page 3: ...ning Systems for Existing Masonry or Factory Built Chimneys and Vents or CAN ULC S640 Standard for Lining Systems for New Masonry Chimneys 24 Permanently seal any opening between the masonry of the fi...

Page 4: ...acement if the appliance is ever removed The removal of any parts that render the fireplace unusable for burning solid fuel requires a permanent label to be affixed by the installer that states the fi...

Page 5: ...ng fuel fired equipment shows evidence of back puffing smoke roll out inefficient operation or excessive smell in the living area b Opening a window or door alleviates any of the above problems or sym...

Page 6: ...e with a metal warning label Permanently attach the warning plate to a visible location in the fireplace After choosing a visible location in the fireplace permanently attach the warning plate by scre...

Page 7: ...your stove and radiates heat more evenly If firebricks were removed to position appliance replace them before firing appliance See figure 7 for proper orientation and positioning Install the back row...

Page 8: ...must meet the three minimum height requirements detailed in figure 8 A minimum draft of 0 05 w c measured in water column is required for proper drafting to prevent back puffing smoke spillage and to...

Page 9: ...ns Under extreme conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wo...

Page 10: ...chemicals or waste in this appliance could result in damages to the heater or result in bodily injury It will also void any warranty on the appliance This heater is designed to burn natural wood only...

Page 11: ...he best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out of the home through the c...

Page 12: ...ance overfiring is when any part of the appliance s exterior or chimney connections glow 5 Close the feed door and secure tightly 6 Adjust the air inlet control as described in the Fueling Instruction...

Page 13: ...ng green wood may cause excessive creosote build up Ignition of creosote or overfiring could cause a chimney fire Chimney fires burn extremely hot and may ignite surrounding combustible materials In c...

Page 14: ...inal disposal The ashes should be retained in the closed container until all cinders have thoroughly cooled SMOKE AND CO MONITORS Burning wood naturally produces smoke and carbon monoxide CO emissions...

Page 15: ...t from glass clip 4 Remove old gasket and clean glass 5 Replace new gasket starting at the bottom of glass working along edges being sure to center gasket channel on glass 6 Trim to length and butt en...

Page 16: ...CORD NEAR OR ACROSS HOT SURFACES CAUTION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE MALE BLACK BLACK BLACK WHITE BLACK WHITE MALE B...

Page 17: ...2 3 12 11 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER USE OF THIRD PARTY COM...

Page 18: ...2 12 29230 Gasket Clamp 1 In Order To Maintain Warranty Components Must Be Replaced Using Original Manufacturers Parts Purchased Through Your Dealer Or Directly From The Appliance Manufacturer Use Of...

Page 19: ...19 Notes...

Page 20: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Page 21: ...ult rieure Lors d une correspondance donnez toujours le num ro de mod le complet qui est inscrit sur la plaque attach e l appareil de chauffage Lors de la commande de pi ces de rechange donnez toujour...

Page 22: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 23: ...tenir la garantie les composants doivent tre remplac s par des pi ces d origine achet es chez votre revendeur ou directement aupr s du fabricant de l appareil L utilisation de composants tiers annuler...

Page 24: ...4 611008 Cabinet droit 1 5 893261 Glissi re d amortisseur 1 6 29301 Accolade coulissante 2 7 893261 Manche en bois 1 8 29300 Couverture 1 9 29298 Amortisseur 1 10 611007 Cabinet gauche 1 10 1 13 8 15...

Page 25: ...sur des surfaces chaudes Mise en garde Le ventilateur doit tre d connect de la source d alimentation lectrique avant de tenter toute op ration de maintenance M le Noire Noire Noire Blanche Noire Blanc...

Page 26: ...r une tanch it correcte si les cordons deviennent effiloch s ou us s remplacez les tout de suite La porte ce cette unit utilise un joint de corde de 1 po de diam tre LE REMPLACEMENT DU CORDON D TANCHE...

Page 27: ...t naturellement des missions de fum e et du monoxyde de carbone CO Le CO est un gaz poison lorsque l exposition se fait des concentrations lev es pour une p riode de temps prolong e Bien que les syst...

Page 28: ...ance calorifique d passant les sp cifications de conception du chauffage peut lui causer des dommages permanents ainsi qu au catalyseur de postcombustion s il est pr sent 7 Videz les cendres r guli re...

Page 29: ...les b ches rouler et heurter la vitre REMARQUE Ne surchauffez pas l appareil une surchauffe se produit lorsqu une partie des connexions ext rieures ou de la chemin e de l appareil brille 5 Fermez la p...

Page 30: ...n bon feu un taux de combustion inf rieur peut tre une meilleure option pour un chauffage efficace Un taux de combustion inf rieur ralentit le flux de chaleur utilisable hors de la maison par la chemi...

Page 31: ...aibles r sultent g n ralement lors de la combustion de bois durs s ch s s ch s l air par rapport aux r sineux ou aux bois durs verts ou fra chement coup s NE PAS BR LER 1 Des ordures 2 Coupures de gaz...

Page 32: ...m me pourrir au lieu de s cher On ne saurait trop soulign que la vaste majorit des probl mes li s au fonctionnement d un insert bois est caus e par le fait que le bois utilis tait trop humide ou avai...

Page 33: ...ges de dos les d versements de fum e et pour maximiser les performances Des jauges pour mesurer le tirage sont facilement disponibles dans les magasins de po les et sont conomiques louer ou acheter De...

Page 34: ...r l appareil Voir figure 7 pour la bonne orientation et le positionnement correct Installez en premier la rang e de briques situ e l arri re suivie par celle de chaque c t et enfin les briques r fract...

Page 35: ...marquer et pr percer les trous n cessaires pour fixer l tiquette 7 Positionnez l appareil dans l ouverture du foyer jusqu ce que la l vre sup rieure de la chemise d air soit align e avec la fa ade du...

Page 36: ...sommet de la chemin e est exig Un adaptateur en acier inoxydable est recommand pour attacher la gaine conduit d acier inoxydable la buse La partie m le ou ondul e de l adaptateur doit tre install e l...

Page 37: ...doivent tre stock es pr cautionneusement si l appareil est d plac Le d montage de n importe quelle pi ce qui rend la chemin e inutilisable pour br ler des combustibles solides implique qu une tiquett...

Page 38: ...x sp cifications CAN ULC S635 Classe 3 norme pour les conduits existants de chemin es industrielles ou de ma onnerie ou CAN ULC S640 norme pour les conduits de nouvelles chemin es de ma onnerie 24 Sce...

Page 39: ...e autre pi ce un espace confin le grenier ou l int rieur d un b timent Ne connectez pas cet appareil un conduit de chemin e d j utilis par un autre appareil 10 NE connectez pas un appareil de chauffag...

Page 40: ...piers pour plus d informations sur les conditions d installation et les restrictions N utilisez pas cet appareil dans un mobile home une maison pr fabriqu e une caravane ou une tente U S Environmental...