X20012 

 

                                

Soft Start with Bypass Contactor-6kW

 

Issue 1 

                                     

User Manual

                                                              Date 4/08/16 

 

Page  1 of 7 

 

 

 

 

 

 

 

 

 

 

 

 

KEY FEATURES 

 

  Soft start 

  Pedestal 

  Easy to install 

 

 

Summary of Contents for SSC-6kW

Page 1: ...X20012 Soft Start with Bypass Contactor 6kW Issue 1 User Manual Date 4 08 16 Page 1 of 7 KEY FEATURES Soft start Pedestal Easy to install ...

Page 2: ...predetermined ramp up time of 1 to 5 seconds It also has a pedestal which is used to adjust the start of the sine wave the range of this is 0 40 The soft start is used to help eliminate high inrush current This helps protect the Load from getting damaged and eliminates nuisance MCB trips INSTALLATION SAFETY FIRST Please read these instructions before installing and operating this product The Soft ...

Page 3: ...upply LIVE to the L terminal NEUTRAL to the N terminal and EARTH to the E terminal The load connects to the terminal block marked LOAD Connect the load LIVE to the L terminal NEUTRAL to the N terminal and EARTH to the E terminal If an external enable signal is used it should be connected to the terminal block marked ENABLE If no enable input is needed a wire link should be inserted into the Enable...

Page 4: ...WIRING DIAGRAM ...

Page 5: ...he cable glands facing down Use these template dimensions to locate the 4 mounting hole centres prior to drilling IMPORTANT Drilling of any holes through the enclosure will immediately invalidate the warranty of the unit The unit MUST be orientated with the cable glands facing down ...

Page 6: ...iate for your applications are available on request CODE IDENTITY DESCRIPTION X10255 SRA Safety requirements Addressing the Low Voltage Directive LVD including Thermal data cooling Live parts warning Earth requirements and Fusing recommendations P01 1 COS UAL Conditions of sale ORDER DETAILS When ordering directly please use the following stock code A403156 NOTE It is recommended that installation...

Page 7: ... u t h p o r t P R 8 4 H Q T e l 4 4 0 1 7 0 4 5 1 6 5 0 0 F a x 4 4 0 1 7 0 4 5 1 6 5 0 1 E m a i l s a l e s u n i t e d a u t o m a t i o n c o m W e b w w w u n i t e d a u t o m a t i o n c o m PRODUCT APPLICATION Transformers Motors Compressors All resistive loads ...

Reviews: