background image

Introduction

unitech PA962

First Steps with the Unitech PA962

NOTE: data you enter may not be properly stored until

the built-in backup battery has been adequately charged.

Please be remided to turn on the back up battery before 

 you charge the terminal

Tour of the unitech PA962

PA962 Front and Left Side

PA962 Back

Additional accessories are shipped separately.

unitech PA962& Accessories

After opening the box, please make sure the
following accessories for the PA962 are present:

Pulling-tags

RF Card Cushion

PA962 Main Body

PA962

Quick Reference Guide

Power system

Power Status Indication

Unpack the box and save the packaging in the
event the unit needs to be stored or returned to
unitech for service.

Check the unit for shipping damage.  If anything
is missing or damaged, notify your unitech sales
representative.

There are three ways to provide power to the PA962:

PA962  CD

Installing the Wireless Local Area 

Network (WLAN) Card

1

2

3

12

14

13

15

400413    Rev . A

Your PA962 is a rugged, compact and lightweight 
palm-size computer.  It utilizes the Windows CE® 
operating system, and incorporates an integral bar 
code scanning laser device, color LCD with touch 
screen, keypad,  IrDA interface, and wireless 
communication capability.  It provides the user with 
a standard Windows-based environment for 
customizing and operating the device.  
This PA962 product reference guide will guide you 
to access your PA962.

Docking Station

RS232/Charging cable,USB/Charging cable

Rechargeable Lithium-Ion battery pack

Charging the Lithium-Ion Battery 

 Pack

The optional Docking Station is a convenient accessory for 
daily use of the PA962. The charging will be completed 
withing 3 hours. Or, when using the included Charging/RS232 
Cable  or Carging / USB cable the charging time of the battery 
pack is about 3 hours. 

Charging the Main and Backup Battery for the First Time

Operating the PA962 for the first time without the AC 
adapter, and without fully charging the  backup battery 
may result in loss of data stored in RAM memory.

Note:  Backing-up data by  backup battery only without the 
main battery installed in the battery compartment may take as 
long as 8 hours.  Therefore, in order to prevent data protection 
failure due to backup battery failure, do not leave the PA962 
without the rechargeable battery pack installed, or without 
connection to AC power for an extended period of time.
It may take up to 72 hours to backup data when the PA962 is 
automatically shut down because of very low battery power 
while the depleted batteries are still installed in the battery 
compartment.

Battery Very Low

Plug with power adapter

Battery Low

Four different icons are displayed on the status bar to indicate 
the on-board power status. 

“Plug” icon:  When displayed, this icon indicates that the battery 
is charging.  The PA962 is either plugged-in via the DC 12V/2A 
power adapter or in the 
docking station. 

“Battery Low” icon:  When displayed indicates the 
battery is low and needs to be charged.  In other words, 
there is no external power supply, the battery charge is low or 
very low, and charging the 
PA962 is recommended.

“Battery Very Low” icon:  When displayed indicates the battery 
is very low.  Stopping the operation and charging the PA962 
immediately is highly 
recommended.

Backup Battery Low

Backup Battery Very Low or 
Backup Battery is not turned on.

No icon:  When displayed means there is no external power 
supply to the PA962 but its 
battery power status is good.

“Backup Battery Low” icon:  When displayed indicates the 
backup battery is low and 
needs to be charged.

“Backup Battery Very Low” icon:  When displayed indicates 
the backup battery is very low.  Stopping the operation and 
charging the PA962 
immediately is highly 
recommended.

Troubleshooting

If the screen is blank or the unit fails to turn on, charge the 
battery for 16 hours.  If the battery is fully charged and the unit 
still fails to turn on, reboot the device by inserting a pin in the 
reset hole.

PCMCIA 
card front side

Insert the RF card into the PCMCIA slot.

Attach pulling-tag to antenna.

Attach the snap-on antenna to the RF card if required (only 
the Cisco card comes with a pre-installed antenna).

Remove the stylus, using the screw driver in 
the stylus to remove the screw, and then 
open the PCMCIA compartment

Power off the PA962

Laser

FCC Statement

The Unitech PA962 is certified in the U.S. to conform to the 
requirements of DHHS/CDRH 21CFR Subchapter J and to the 
requirements of IEC 825-1.  Class II and Class 2 products are 
not considered to be hazardous.  The PA962 contains 
internally a Visible Laser Diode (VLD) whose emissions do not 
exceed the maximum limits as set forth in the above 
regulations.  The scanner is designed so that there is no 
human access to harmful laser light during normal operation, 
user maintenance or during prescribed service operations.

CAUTION

 - Use of controls or adjustments or performance of 

procedures other than those specified herein may result in 
hazardous laser light.  Use of optical instruments with the 
scanner will increase eye hazard.  Optical instruments include 
binolulars, microscopes, and magnifying glasses.  This does 
not include eye glasses worn by the user.

The laser safety warning label required by the DHHS/IEC for 
the PA962’s optional laser scanner module is located on the 
memory compartment cover, on the back of the unit.

This is a FCC Part 15 Class B product.  In a domestic 
environment this product may cause radio interference, 
in which case the user may be required to take adequate 
measures.

www.unitech-adc.com

Battery pack

Stylus

Stylus

This stylus is design for tapping 
screen and also for accessing 
batter door via the screw driver
 in the stylus.

Bar Code Laser Scanner

Right Side Scanner 
Trigger

Press it to enable 
laser sccanner to 
read bar code.

Keypad

Touch Screen

RS232/USB/Charging Port

IrDA port

Reset Hole

Push enclosed 
button for system
 warm-start

CF slot compartment

Please remove the 
battery door to access 
CF slot.

Battery compartment

Install Lithium-ion battery 
pack here.

PCMCIA compartment

Install PC card here.

Note:  Before using the PA962 for the first time, charge 
the unit for 16 hours to fully charge the empty  backup battery. 

Check Battery Status: 

The battery menu item will show the status 
of the main and backup batteries.  There 
are 3 kinds of status indicators — “Good”, 
“Low” and “Very Low”. Bold characters 
indicate the actual status, e.g. battery icons 
in the illustration at right mean both the main 
and backup batteries are “GOOD”.

It is necessary to charge the battery when “Low” or “Very Low” 
are displayed in bold characters.  If “Low” or “Very Low” are 
still displayed after charging, please contact Unitech 
Technical Support.

PA962

Quick Reference

Guide

Laser Scanner

The PA962 has an integrated laser scanner, which 
reads all major bar code labels with excellent performance. 
Trigger keys are located on the left and right sides of the unit.  
Press either one to activate the laser scanner. 
The PA962 also has a built-in Scanner Setting.exe program 
that allows the user to test the barcode scan function. 
Scanner Setting.exe is located in directory \Windows\Control 
and is also accessible by shortcut via “Setting\Control” on the 
Start menu. 

European Conformity Statement

Declaration of Conformity with Regard to the R&TTE 
1999/5/EC and EMC 89/336/EEC directives.

CF slot drawer for PA962