Page 1: ...OFF GRID PROFESSIONAL GAS RANGETOP UGP 30E CT2 JUNE 2015 OWNER S GUIDE Read and save these instructions serial number ...

Page 2: ...nual with the range How to Obtain Service and or Parts When your rangetop does not operate in accordance with the instructions in the manual you should contact the dealer in your immediate vicinity for service Or the purchaser may contact the service organization noted on the warranty This manual contains information for Important Safeguards Installation Use and Care Certain rangetops come equippe...

Page 3: ...A N U F A C T U R E D A N D C E R T I F I E D B Y Unique Gas Products Ltd 2245 Wyecroft Road Oakville Ontario Canada L6L 5L7 Ph 905 827 6154 Toll Free 1 877 427 2266 Fax 905 827 2027 www UniqueOffGrid com ...

Page 4: ...Page 15 17 Cleaning the Range top Page 18 19 How to Gain Access to the Battery Page 19 Gas Rangetop Conversion and Adjustment Guide Pages 20 23 Troubleshooting Pages 24 25 Wiring Diagram Page 26 Parts Diagram and List Page 27 29 Warranty Page 30 Note For warranty and service information please see attachments packaged with rangetop ...

Page 5: ...top only as instructed in this manual These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operating and maintaining the appliance Record in the space provided below the Model No and Serial No of this appliance These numbers are found on the serial plate located at back of rangetop Model No ______...

Page 6: ...ontact with other appliances or furniture Be safety conscious The preparation of food on a rangetop requires temperatures that could cause severe burns Before using this new appliance carefully read and follow all instructions The California Safe Drinking Water and Toxic Enforcement Act of 1986 Proposition 65 requires the Governor of California to publish a list of substances known to the State of...

Page 7: ...he event it is necessary to shut off gas supply to the rangetop during an emergency USER SERVICING Do not repair or replace any part of the appliance unless specifically recommended in this owner s guide All other servicing should be done only by a qualified technician This will reduce the risk of personal injury and damage to the rangetop Storage in or on appliance Flammable materials should not ...

Page 8: ...proper relationship of utensil to burner will improve efficiency Know which knob controls each burner Place a pan of food on the burner before turning it on and turn the burner off before removing the pan Always turn to the ignite position when lighting top burners Then adjust the flame size so it does not extend beyond the edge of the utensil Utensil handles should be turned inward and not extend...

Page 9: ...ck the manufacturer s recommendations for rangetop use Do not place plastic salt and pepper shakers spoon holders or plastic wrappings on top of the rangetop These items could melt or ignite Potholders towels or wooden spoons could catch fire if place too close to the flame Do not use a wok equipped with a metal ring that extends beyond the burner Because this ring traps heat the burner and grate ...

Page 10: ...rangetop install it or have them recommend a qualified installer Installation must conform with local codes In the absence of local codes the installation must conform with the National Fuel Gas Code ANSI Z223 1 Latest Edition in the U S A or the CAN CGA B149 1 or 2 Installation Codes in Canada The rangetop should be connected to the supply line with 1 2 inch black iron pipe or a certified flexibl...

Page 11: ...s supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig CLEARANCES All units must be installed in accordance to minimum rear and side wall clearances and clearances extended vertically above cooking top which are stated on the serial plate the serial plate is located on the b...

Page 12: ...rranty Any expenses incurred due to such situations will not be paid by the manufacturer of the appliance Note Based on 24 61 cm deep cabinet This rangetop may be installed directly adjacent to existing 36 91 4 cm high base cabinets The rangetop CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 91 4 cm high There must be a min...

Page 13: ...nets above the rangetop must be a minimum of 42 106 7 cm above the rangetop cooking surface for the full width of the rangetop This minimum height requirement does not apply if a rangetop hood is installed over the cooking surface Wall Installation If a range hood is installed above the rangetop maintain a 30 76 2 cm minimum clearance between the rangetop and the bottom of the range hood The range...

Page 14: ...o existing 36 91 4 cm high base cabinets The rangetop CANNOT be installed directly adjacent to sidewalls tall cabinets tall appliances or other side vertical surfaces above 36 91 4 cm Note There must be a minimum of 6 15 2 cm clearance from rear of rangetop to a combustible wall Clearances from non combustible materials are not part of the ANSI Z21 1 scope and are not certified by CSA Clearances t...

Page 15: ...his 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wall cabinets above the rangetop must be a minimum of 42 106 7 cm above the rangetop cooking surface for the full width of the rangetop This minimum height requirement does not apply if a rangetop hood is installed over the cooking surface Make sure there is a power outlet within the reach of the rangetop s power ...

Page 16: ...U G P 3 0 E C T 2 12 Make the countertop cut out following the dimensions given in the illustration above Base below rangetop must be of a non combustible material ...

Page 17: ...ure of natural gas supplied to the regulator should be between 4 and 5 of water column For LP gas the pressure supplied must be between 10 and 12 of water column When checking for correct operation of the regulator the inlet pressure must be at least 1 more than the operating manifold pressure as given above The pressure regulator located at the inlet of the rangetop manifold must remain in the su...

Page 18: ...etop knows where and how to shut off the gas supply to the cook top 2 Use a flexible gas line to connect to the 1 2 fitting located on the bottom right hand corner underneath the rangetop 3 When all connections have been made be sure all rangetop controls are in the off position and turn on the main gas supply valve Check for gas leaks by using a 75 water 25 dish washing soap solution If a gas lea...

Page 19: ...hese instructions A high flame on a surface burner is both inefficient and unsafe The flame should always be adjusted so that it is no larger than the bottom of the pan Fluctuations in flame size could be caused by pressure variations improperly positioned burners damage or debris Surface Burner Ignition To light the top burners push and turn the appropriate control knob counter clockwise to the H...

Page 20: ...tting will give the best simmer results Small flames offer precise cooking performance for delicate foods keeping food warm melting chocolate or butter and for cooking that needs low heat for a long period of time A larger flame setting provides the maximum heat that is available on your range This setting should be used for higher temperature cooking such as stir fries boiling water or cooking pa...

Page 21: ...o hold the knob down until the flame lights Once the burner is lit hold in for a few extra seconds to warm up the thermocouple so the electromagnet in the burner valve stays in the open position once you release 4 After lighting the flame turn the control knob to adjust the flame size as required 5 In the instance of a power outage when using the 110V electronic ignition option one can still use t...

Page 22: ...nywhere in or on the rangetop This will make future cleaning more difficult and may present a fire hazard Do not use any abrasive or harsh cleaners cloths scouring pads or steel wool on the exterior these will scratch and damage the appearance Do not use a steam cleaner to clean any part of the range or oven Do not perform any cleaning or maintenance on parts not specifically listed in the chart b...

Page 23: ...s to dry thoroughly before using the rangetop HOW TO GAIN ACCESS TO THE BATTERY COMPARTMENT Locating and Replacing Batteries 1 Location of the battery is on the left front underside of the rangetop 2 Using a Philips screwdriver remove the screw allowing for the access door to open 3 Replace the 9 volt battery 4 Secure the battery and then reverse step 2 ...

Page 24: ...e for future use make sure you note which orifices are for which burner if you plan on converting back to NG The inlet pressure of the gas supply shall be in accordance with the nominal inlet pressure of the regulator used on the rangetop or 1 2 psig maximum The rangetop should be tested by pressurizing the regulator with an inlet pressure at least 1 inch water column above the manufacturer s spec...

Page 25: ...ench to remove the orifices Each orifice can be accessed easily 8 Remove all NG orifices and place in a separate bag and store with your manual for future use Label your orifices as you remove from the rangetop 9 Take the LPG orifices provided and install as shown below in the chart each orifice is stamped with the size You may require a magnifying glass to see this stamping Orifice removed ...

Page 26: ...are installed replace all burners and burner caps then fire up the burners to check the minimum flame height 11 Minimum flame height should be approx tall You will want a small minimum flame for simmering There is a small adjustment screw located on the valve itself the front control panel must be removed in order to make the adjustment 12 To remove the control panel remove the two bottom screws h...

Page 27: ...can make the adjustment Turn to minimum flame then adjust the screw counter clockwise for a smaller flame and clockwise for a larger flame Replace the lid burners burner caps and grates adjust and recheck the flame 15 Once your happy with the minunim flame height replace the front control panel with the two screws earlier removed Notch Adjustment screw ...

Page 28: ...ctions BURNER FLAMES ARE VERY LARGE AND YELLOW Burner bezel ports are clogged Burner ports or burner caps are not positioned properly Rangetop is being operated with the wrong type of gas Regulator is not installed is faulty or is set for the wrong type of gas Clean burner bezel ring ports with straightened paper clip needle or wire Remove and carefully re install burner bezel and caps Ensure that...

Page 29: ...area See Care and Cleaning for instructions Once clean reignite top burners NO IGNITION SPARK Dead batteries or ignition module failed Replace batteries and attempt ignition If there is still no spark ignition the rangetop burners can still be used To light them 1 Holding a lit match to the flame spreader push in on the control knob and turn counter clockwise to LIGHT 2 When the flame is burning a...

Page 30: ...U G P 3 0 E C T 2 26 Wiring diagram UGP 30 CT2 ...

Page 31: ...U G P 3 0 E C T 2 27 Parts Lists and Diagram ...

Page 32: ...orate box UGP HX04060569 A0 17 Aluminum tube A UGP HX11020102 A0 18 Aluminum tube B UGP HX11020103 A0 19 Back panel UGP HX04040525 A0 20 Relay UGP HX07080010 A0 21 Ignitor UGP HX07070185 A0 22 Back panel UGP HX04050698 A0 23 Plug nut Incl with part 31 23 Knob UGP HX22990046 A0 24 Left side panel UGP HX04020669 A0 25 Cooktop Base frame UGP HX20990161 A0 26 Battery holder UGP HX04020663 A0 27 Plate ...

Page 33: ... 29 Item Description Part 40 Control panel UGP HX04020693 A0 41 18 000 BTU Single valve UGP HX09010023 A0 41 12 000 BTU Single valve UGP HX09010007 A0 42 Bezel UGP HX14040009 A0 44 Front support N A 45 Rear support N A ...

Page 34: ...nts or chemicals accident improper installation or service delivery damage or other than normal household use and service This UNIQUE appliance must be serviced regularly as outlined in the Owners Manual Neither Unique Gas Products Ltd nor the selling dealer will be liable for direct or indirect loss of foods caused by failure in operation In case of damage the owner must provide proof of purchase...