background image

 

 

 

 

UP-2000CL

 

 Digital CCD Camera 

User's Manual 

 

091-2000 V.1.4 

02-03-17

 

 

 
 

 

 
 

 
       

Summary of Contents for UP-2000CL

Page 1: ...UP 2000CL Digital CCD Camera User s Manual 091 2000 V 1 4 02 03 17 ...

Page 2: ...2 Precautions 2 Limited Warranty 2 1 Introduction 3 2 Camera Setup 5 3 Camera Functions 5 4 RS 232C Communication Control 9 5 Digital Interface Timing 10 6 Camera Functional Timing 11 7 Camera Accessories 13 8 Technical Support 13 ...

Page 3: ...ts Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or damages due to defects in material or workmanship which occur during normal use It does not cover damages or failures which result from shipment mishandling abuse misuse or modification A Return Materia...

Page 4: ... 1 2 Progressive Scan CCD Imager 1620 x 1236 active pixels 16 Hz frame rate 2 x 2 810 x 618 Binning at 32 FPS 10 bit Camera Link output Analog output Full frame shutter 1 16 1 40 000 sec 58 dB Asynchronous reset at full frame shutter 40 MHz data clock RS232C interface control C mount lens 1 3 Applications UP 2000CL applications include machine vision automated inspection motion capture and analysi...

Page 5: ...PS for 2x2 binning Sync HD 19 979 KHz VD 16 009 Hz Digital Video Output Camera Link format Analog Video Output 1 V p p 75ohm BNC or 12 pin Hirose S N Ratio 58 dB Min Illumination 0 1 lux Gain MGC Gamma 1 0 Electronic Shutter 1 16 1 40 000 selectable Lens Mount C Mount Operating Temperature 10 C 55 C Power Requirement 12V DC 300mA 3 6 W Dimension 50mm x 39mm x 83mm Ext Sync Internal External Auto S...

Page 6: ...3 1 12 Pin Connector The 12 pin Hirose connector is located on the rear panel of the camera All ground signals on pin 1 3 5 and 8 are common grounds 12 V DC input is recommended on pin 2 but this camera should withstand 12 V 1V input voltage Make sure to set the NM AM switch to NM position for external HD and VD locking Figure 2 below shows a top view of the 12 pin Hirose connector Pin No UP 2000C...

Page 7: ...eed Double Speed 2x2 binning Shutter Speed sec NM Mode Asynchronous Capture sec AM Mode Shutter Speed sec NM Mode Asynchronous Capture sec AM Mode 0 Normal 1 16 Off No shutter 1 32 No shutter 1 Gain Adjustment 1 50 1 500 1 50 1 500 2 Reference Adjustment 1 100 1 1 000 1 100 1 1 000 3 Factory Page 1 200 1 1 500 1 200 1 1 500 4 User Page 1 1 400 1 2 000 1 400 1 2 000 5 User Page 2 1 500 1 3 000 1 50...

Page 8: ...ttings can be saved into four different user pages Once the user page is saved and set between shutter speeds 4 and 7 it will be activated as long as the camera is powered ON User Page works in both rear plate control and RS232C communication selections 3 5 Gain Control AGC MGC Note This gain potentiometer only applies to cameras without Up Down switch on rear plate Manual gain control MGC MGC is ...

Page 9: ...3 Video LEN and FEN data output 7 20 SerTC SerTC Rx Rx Differential pair serial communications from frame grabber 8 21 SerTFG SerTFG Tx Tx Differential pair serial communications to frame grabber 9 22 CC1 CC1 HD HD Camera Control 1 CC1 Horizontal signal input 10 23 CC2 CC2 VINIT VD VINIT VD Camera Control 2 CC2 Vertical signal or asynchronous reset input 11 24 CC3 CC3 Reserved Reserved for custom ...

Page 10: ...actor of 1 If a number is entered then number will be added to stored gain gd Gain decrease Hexadecimals 000 3ff Same as gi above except it will be decreased gn Gain number Hexadecimals 000 3ff Refer to the gain curves below for details Only one curve applies to each camera depending on camera model contact UNIQ for further details bi Reference increase Hexadecimals 000 3ff If no number entered re...

Page 11: ... 1 Pixel Clock 5 2 Line Enable 5 3 Frame Enable 5 4 Pixel Clock for 2 x 2 Binning 5 5 Line Enable for 2 x 2 Binning 5 6 Frame Enable for 2 x 2 Binning Note 1 1 N 25 nsec 50 nsec for 2 x 2 binning 2 1 H 2000 N 1000 N for 2 x 2 binning ...

Page 12: ...er speed position 0 16 fps 6 2 Free Run shutter speed position from 1 to F 6 3 Asynchronous Capture shutter speed position 0 6 4 Asynchronous Capture shutter speed position from 1 to E 6 5 Asynchronous Capture with Pulse Width Control shutter speed F ...

Page 13: ...gure 10 External Synchronization and Gen lock Timing 6 7 Integration via 12 pin Hirose connector ONLY The UP 2000CL camera can be integrated up to 2 seconds without severe noise or dark current effect To start integration pin 11 same as pin 27 of 40 pin digital connector of the 12 pin connector must be connected to GND or 0V The integrated video will be shifted out following the next vertical driv...

Page 14: ...mera There are a variety of C mount lenses in the market that works with UP 2000CL camera Make sure the quality and specification of the lens match the camera s application Some of the most popular lenses in the market such as Cosmicar Fujinon Rodenstock and Schneider are recommended 7 3 Camera Link Cable Camera Link cable can be purchased from 3M Mouser Digi Key and frame grabber vendors 8 Techni...

Reviews: