background image

 
 

 

 

4

 

 

 

 

1.5 Camera Specifications 
 

Model                                         

UP-1800CL-12B 

CCD Sensor 

2/3” Exview HAD progressive scan interline-transfer CCD 

Chip Size 

10.20 mm x 8.30 mm 

Effective Pixels (H x V) 

1390 x 1037 

Unit Cell Size (H x V) 

6.45 

µ

m x 6.45 

µ

Pixel Clock 

27 MHz 

Frame Rate 

15 FPS (30 FPS for 2x2 binning) 

Sync. 

HD: 15.733 KHz; VD: 14.998 Hz 

Digital Video Output 

Camera Link format 

Analog Video Output 

1 V p-p, 75ohm (BNC or 12 pin Hirose) 

S/N Ratio 

<66 dB  

Min. Illumination 

0.02 lux 

Gain 

MGC 

Gamma 

1.0 

Electronic Shutter 

1/15 ~ 1/32,000 selectable 

Lens Mount 

C-Mount 

Operating Temperature 

-10 

°

 +55 

°

Power Requirement 

12V DC, 280mA, 3.4 W 

Dimension 

50mm x 39mm x 83mm 

Ext. Sync. 

Internal/External Auto Switch  

Asynchronous Reset 

Standard 

Weight 

200 g 

 

 
 

1.6 Camera Dimension 
 
 

 

                      

 

 

 
 
 

Summary of Contents for UP-1800CL-12B

Page 1: ...UP 1800CL 12B Camera Link Camera User s Manual 091 1802 V 1 4 08 09 17 ...

Page 2: ...2 Precautions 2 Limited Warranty 2 1 Introduction 3 2 Camera Setup 5 3 Camera Functions 5 4 RS 232C Communication Control 9 5 Digital Interface Timing 10 6 Camera Functional Timing 11 7 Camera Accessories 13 8 Technical Support 13 ...

Page 3: ...ts Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or damages due to defects in material or workmanship which occur during normal use It does not cover damages or failures which result from shipment mishandling abuse misuse or modification A Return Materia...

Page 4: ...cations 1 2 Features 2 3 Exview HAD NIR Progressive Scan CCD Imager 1390 x 1037 active pixels 15 Hz frame rate 2 x 2 694 x 518 Binning at 30 FPS 12 bit RS 644 LVDS Camera Link digital output Analog output Full frame shutter 66 dB Asynchronous reset at full frame shutter 27 MHz pixel clock RS 232C interface Control C mount lens 1 3 Applications UP 1800CL 12B applications include microscopy machine ...

Page 5: ...or 2x2 binning Sync HD 15 733 KHz VD 14 998 Hz Digital Video Output Camera Link format Analog Video Output 1 V p p 75ohm BNC or 12 pin Hirose S N Ratio 66 dB Min Illumination 0 02 lux Gain MGC Gamma 1 0 Electronic Shutter 1 15 1 32 000 selectable Lens Mount C Mount Operating Temperature 10 C 55 C Power Requirement 12V DC 280mA 3 4 W Dimension 50mm x 39mm x 83mm Ext Sync Internal External Auto Swit...

Page 6: ...1 12 Pin Connector The 12 pin Hirose connector is located on the rear panel of the camera All ground signals on pin 1 3 5 and 8 are common grounds 12 V DC input is recommended on pin 2 but this camera should withstand 12 V 1V input voltage Make sure to set the NM AM switch to NM position for external HD and VD locking Figure 2 below shows a top view of the 12 pin Hirose connector Pin No UP 1800CL ...

Page 7: ... to DS this time for 2x2 binning shutter speed selection For asynchronous capture applications set NM AM mode to AM location Position No Functional Select NS Shutter Speed Select DS Shutter Speed sec NM Mode Shutter Speed sec DS Mode Asynchronous Capture for normal and binning sec AM Mode 0 Normal 1 15 Off 1 30 Off No shutter 1 Gain Adjustment 1 30 1 60 1 500 2 Reference Adjustment 1 60 1 80 1 750...

Page 8: ...can be saved into four different user pages Once the user page is saved and set between shutter speeds 4 and 7 it will be activated as long as the camera is powered ON User Page works in both rear plate control and RS232C communication selections 3 5 Gain Control AGC MGC Manual gain control MGC MGC is standard factory setting on this camera The manual gain control can be adjusted from 9 dB to 18 d...

Page 9: ...A3 Video LEN and FEN data output 7 20 SerTC SerTC Rx Rx Differential pair serial communications from frame grabber 8 21 SerTFG SerTFG Tx Tx Differential pair serial communications to frame grabber 9 22 CC1 CC1 HD HD Camera Control 1 CC1 Horizontal signal input 10 23 CC2 CC2 VINT VD VINT VD Camera Control 2 CC2 Vertical signal or asynchronous reset input 11 24 CC3 CC3 Reserved Reserved for custom o...

Page 10: ... If no number entered gain will be increased by factor of 1 If a number is entered then number will be added to stored gain gd Gain decrease Hexadecimals 000 3ff Same as gi above except it will be decreased gn Gain number Hexadecimals 000 3ff Refer to the gain curves below for details bi Reference increase Hexadecimals 000 3ff If no number entered reference will be increased by factor of 1 If a nu...

Page 11: ...10 5 Digital Interface Timing 5 1 Pixel Clock 5 2 Line Enable 5 3 Frame Enable 5 4 Pixel Clock for 2x2 binning mode 5 5 Line Enable for 2x2 binning mode 5 6 Frame Enable for 2x2 binning mode ...

Page 12: ...er speed position 0 15 fps 6 2 Free Run shutter speed position from 1 to F 6 3 Asynchronous Capture shutter speed position 0 6 4 Asynchronous Capture shutter speed position from 1 to E 6 5 Asynchronous Capture with Pulse Width Control shutter speed F ...

Page 13: ... Synchronization and Gen lock Timing 6 7 Long Term Integration via 12 pin Hirose connector ONLY The UP 1800CL 12B camera can be integrated up to 2 seconds To start integration pin 11 of the 12 pin connector must be connected to GND or 0V The integrated video will be shifted out following the next vertical drive after pin 11 goes back to high or 5V level as shown in figure 9 below If a frame grabbe...

Page 14: ...r UP 1800CL 12B camera There are a variety of C mount lenses in the market that works with UP 1800CL 12B camera Make sure the quality and specification of the lens match the camera s application Some of the most popular lenses in the market such as Cosmicar Fujinon Rodenstock and Schneider are recommended 7 3 Camera Link Cable Camera Link cable can be purchased from 3M Mouser Digi Key and frame gr...

Reviews: