(5) DSP check
Check the backlight and status indicator lamp.
The backlight turns bright by pressing the [Bright] button, and turns
dark by pressing the [Dark] button.
The backlight goes out when the [Light Out] button is pressed, and
after that, it recovers when the screen is touched.
The status indicator lamp lights in green and red alternately.
How to set
(6) PUI check
The pulse input can be confirmed. Press the button of the connector
being currently input. The pulse cycle is displayed.
How to set
(7) COM check
The data displayed under "Transmit data" is sent by pressing the
[Trns.] button.
Under "Receive data", externally transmitted data is displayed.
How to set
Please transmit something information sentence from connected equipment side to the check on the
reception. The data received to "Receive data" is displayed. Please confirm the cable or the setting of
communication condition when it is not correctly displayed, when "Parity" or "Frame" lights in red.
Please press the [Trns.] button to the check on the transmission. The data displayed in "Transmit
data" is transmitted. It will be confirmed to receive it correctly on connected equipment side. Please
confirm the cable or the setting of communication condition when it is not possible to confirm it.
■
Password
This setting is for maintenance and inspection. Do not operate.
SET.
DSP Check
Self Check
→
→
SET.
PUI Check
Self Check
→
→
SET.
COM Check
Self Check
→
→