4-5.
Equivalent Input Calibration
Set the capacity of UTM
Ⅱ
.
≪
Setting value
≫
-99999 to 99999 (0 is excluded.)
How to set
1.
Press the [SET.] button. (see P.17)
2.
Press the [Calibration] button. (see P.19)
3.
Press the [Equiv.Cal.] button.
4.
Input the capacity with the numerical keys.
Set with a decimal place. Press the [OK]
button to perform calibration.
■
Registration method at decimal place
Example)
The indicated value is made "200.0" by equivalent input calibration.
It is a specification to which the decimal place is input with the numerical keys.
Please input it in the image that operates the calculator.
Please put it again from the start pushing the [C] button when you correct it.
SET.
Calibration
Page 1
→
→
→
→
The display of the decimal place
→
→
Press
of the input value moves.
- Please put it again from the start pushing the [C] button when the decimal place
is lost.
- All set values concerning the load synchronize with the decimal place of the
indicated value (capacity).
Point