4
SETTINGS AND CALIBRATIONS
41
Chapter
4
SETTINGS AND CALIBRATIONS
6.
Equivalent Input Calibration
Input the relationship between the number of pulses (rated
output) and displacement value (display value) determined from
the data sheet of the rotary encoder. Also, set the decimal place
here. Input the decimal point together when inputting the display
value.
Setting range
Rated output (number of pulses)
(1 to 1000000)
Operation
Display value (displacement value) (-99999 to 99999)
Main screen
→
Setting
→
First Setting
→
X-axis Setting
→
Next
→
Equiv. Cal.
7.
Actual Load Calibration
Move the cylinder, and input its position. Also, set the decimal
place here. Input the decimal point together when inputting the
calibration value.
Setting range
Calibration value
(-9999 to 32000)
Operation
Display value
(display only)
Main screen
→
Setting
→
First Setting
→
X-axis Setting
→
Next
→
Actual Cal.
8.
Measurement Length
Set the length for waveform acquisition.
Operation
Setting range (2000, 4000, 6000, 8000, 10000)
Main screen
→
Setting
→
First Setting
→
X-axis Setting
→
Next
→
Measure Length
9.
Displacement Positioning
Set the position for displacement adjustment at power-on, on the
Main screen, and by external input.
Operation
Setting range (-9999 to 32000)
Main screen
→
Setting
→
First Setting
→
X-axis Setting
→
Next
→
Next
→
DPM Positioning
10.
Digital Filter
Displacements are moving-averaged by the set number of times.
Operation
Setting range (0, 2 to 999 Times)
Main screen
→
Setting
→
First Setting
→
X-axis Setting
→
Next
→
Next
→
Digital Filter