20
4
Torque Settings
20
Torque Settings
Chapter
4
Unit (UNIT)
Set the unit of value to display.
<Setting range>
deg, rad
Direction (DIRECTION)
Set the rotation direction of UTM
Ⅱ
.
<Setting range>
NORMAL, REVERSE
- NORMAL
Select this option when using the UTM
Ⅱ
clockwise viewing from the drive
side.
- REVERSE
Select this option when using the UTM
Ⅱ
counterclockwise viewing from the
drive side.
* Change the setting if the direction of rotation does not conform with increase/decrease of
angle display.
Minimum scale (MIN. SCALE) (optional if there is no change)
Set the minimum unit of rotary encoder such as scale interval and scale division.
<Setting range>
0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100
Zero clear (ZERO CLEAR) (optional if there is no change)
Set the timing to reset the angle display to zero.
The angle display will be reset to zero at a specified number of revolutions.
<Setting range>
1 to 2500 [R]
Zero clear from the recording start (REC.ST.CLR)
Set whether or not to reset the angle to zero at the start of recording.
<Setting range>
OFF, ON
- OFF
The angle is not reset to zero at the start of recording and displayed on a graph as is.
- ON
The angle is reset to zero at the start of recording and displayed so on a graph.
If PEAK ANG (peak hold (angle)) is selected in hold mode, the peak angle can be
identified. You can easily check the amount of angle movement from the
measurement starting point using this function.