41
5
OPTION
41
OPTION
Chapter
5
Select a BCD input logic.
5-3.
RS-232C Interface (Option)
The RS-232C is an interface to take in RS-232C spec data, codes and command signals to the
M252B.
Signal level
RS-232C spec
Transmission distance
Approx. 15m
Transfer system
Start/stop synchronous system, full duplex communications
Transfer speed
1200, 2400, 4800 or 9600 bps selection
Bit configuration
Start bit:
1
Character length:
7 or 8 bit selection
Stop bit:
1 or 2 bit selection
Parity bit:
Non, odd or even selection
Code
ASCII
Connector
D-Sub 9pin male (CN33)
Necessary settings
46: RS-232C transmission rate
47: RS-232C parity bit
48: RS-232C data/stop bit
49: RS-232C terminator
50: RS-232C answer mode
Name of setting
42: BCD Data Logic
43: BCD Minus Logic
44: BCD Over Logic
45: BCD Strobe Logic
Selection item
0. Negative logic
1. Positive logic
Initial value
0. Negative logic (all)
Reference
Logic settings can be made separately for Data/Code, Minus, Over, and Strobe.
42: BCD Data Logic
43: BCD Minus Logic
44: BCD Over Logic
45: BCD Strobe Logic
How to enter the option mode