6.FUNCTION SETTING
42
Tare subtraction can be executed by the signal from the external in/output connector on the rear Panel (Pin 5).
6-2-2. Preset tare weight 1/ Preset tare weight 2
Tare is Subtracted and Net weight is zeroed.
Set tare by pressing PRESET TARE WEIGHT 2 then set PRESET TARE WEIGHT 1 ON.
1) PRESET TARE WEIGHT 1
(ON/OFF)
2) PRESET TARE WEIGHT 2
(input range: 0 ~ 99999)
Operation
6-2-3. Auto accumulation command
Select whether to automatically accumulate the RESULT of the F805AT-CK (ON) or not (OFF).
When Complete output signal turns ON, do auto accumulation to the active weighing code, value,
times and statistical data. Also send out auto printer command via SI/F and SI/FII interfaces.
Accumulation is executed only when over/under judgment is made.
If the setting of OVER/UNDER COMPARISON is OFF, accumulation is not performed. Select from
ON/OFF.
1) ON
Automatic accumulation is performed.
2) OFF
Automatic accumulation is not performed.
Operation
★
★
Tare OFF
Tare OFF
★
Pulse width: 50ms or more
External input
(pin 5)
MODE
FUNCTION
→
→
Press
PRESET TARE WEIGHT 1
→
1)
Select ON/OFF
OK
→
MODE
FUNCTION
→
→
Press
PRESET TARE WEIGHT 2
→
2)
Input 0 ~ 99999
OK
→
TARE SUBTRACTION and PRESET WEIGHT 1 functions independently.
When
is pressed, Tare Subtraction will be executed at once then NET
becomes 0 while PRESET TARE WEIGHT 1 is ON.
TARE
MODE
FUNCTION
AUTO ACCUM. COMMAND
→
→
Press
→
Select ON/OFF
OK
→