5.CALIBRATION
40
5-7-2. Span error measure
A function to measure span error point. This function takes measurements disregarding
the current [SPAN ERROR SET] setting (e.g. assuming that it is set to 0%). As in the
case with “Zero error measurement”
,
up to three independent reference points can be
defined on the conveyer and allows simultaneous measurements.
Pressing
will register the average error in your system (current [SPAN
ERROR SET] settings will be overwritten).
Operation
5-7-3. Zero error set
This function set the value to zero error point.
Operation
5-7-4. Span error set
This function set the value to span error point.
Operation
OK
Note
Using this function during operation ignores the current [SPAN ERROR
MEASUREMENT] setting in TOTAL accumulation.
MODE
FLOW CALIBRATION
→
→
SPAN ERROR MEASURE
:Range: -999.99 – +999.99% (5 digits, fixed decimal point)
MODE
FLOW CALIBRATION
→
→
ZERO ERROR SET
Range: -999.99 – +999.99% (5 digits, fixed decimal point)
MODE
FLOW CALIBRATION
→
→
SPAN ERROR SET