5.CALIBRATION
37
5-6-8. Decimal place (weight)
Define the data representation format (decimal point place) for the measurement items
that are defined as variable digits. See "SETTING ITEMS LIST" , on page 177 for
Operation
further information.
5-6-9. Gravitational acceleration
When the load cell is used in a remote location from where it was calibrated, a factor is
required to compensate the difference in gravitational acceleration between the two
locations. This compensation is not required if the distance between these locations is
not large.
In the table below, search the region number (01-16) of the location where weight
calibration takes place, and enter the number into the instrument when you perform
weight calibration.
Next, search the region number where the instrument is actually used, and enter the
number into the instrument.
This guarantees that the regional difference of gravitational acceleration is
automatically compensated.
Operation
Selectable format: 0, 0.0, 0.00, 0.000
MODE
WEI.CALIBRATION
→
→
DECIMAL PLACE(WEIGHT)
PAGE
→
01
9.806
02
9.805
03
9.804
04
9.803
05
9.802
06
9.801
07
9.800
08
9.799
09
9.798
10
9.797
11
9.796
12
9.795
13
9.794
14
9.793
15
9.792
16
9.791
Allowable range: 01 – 16 (2 digits)
MODE
WEI.CALIBRATION
→
→
GRAV.ACCELERATION
PAGE
→
Summary of Contents for F805AT-BC
Page 1: ...F805AT BC BELT SCALE CONTROLLER 15 Feb 2019 Rev 1 03 OPERATION MANUAL...
Page 15: ...CONTENTS XIV M E M O...
Page 202: ......