9.OPTION (Option card required)
135
9-1-10. Output selection input
This input specifies the type of BCD data.
9-1-11. BCD out setting
Operation
1
)
2
)
Select a desired data update rate and press “OK” to confirm.
Selection 4 Selection 2 Selection 1
Weighing value
Open
Open
Open
Belt speed
Open
Open
Close
Weight density
Open
Close
Open
Feed rate
Open
Close
Close
Load ratio
Close
Open
Open
Feed ratio
Close
Open
Close
Gross weight
Close
Close
Open
Total (upper 4 digits)
Close
Close
Close
Total (lower 5 digits)
MODE
OPTION
→
BCD DATA UPDATE RATE
PAGE
→
→
Data update rate and strobe width:
200 times/sec
STROBEwidth
approx. 2.5mSec
100times/sec
STROBEwidth
approx. 5mSec
50times/sec
STROBEwidth
approx. 10mSec
20times/sec
STROBEwidth
approx. 25mSec
10times/sec
STROBEwidth
approx. 50mSec
5times/sec
STROBEwidth
approx. 100mSec
2times/sec
STROBEwidth
approx. 250mSec
1time/sec
STROBEwidth
approx. 500mSec