8.INTERFACE
105
Assigning ID number (SI/F II ID)
This function defines the F805AT-BC’s ID number on the SI/F II network. Enter the
desired ID number and press
to confirm.
Operation
8-3. RS-232C Interface
8-3-1. Communication specifications
Specifications
Signal Level:
RS-232C compatible
Transmission Distance: Approx. 15 m
Transmission method:
Asynchronous, full-duplex
Transmission speed:
1200, 2400, 4800, 9600, 19200, or 38400 (selectable)
Bits configuration:
Start bit:
1
Character length:
7 or 8 (selectable)
Stop bit:
1 or 2 (selectable)
Parity:
none, odd or even (selectable)
Communication code:
ASCII
Connector pin assignment
OK
Input Range: 0-3
MODE
COMMUNICATION
→
→
PAGE
PAGE
→
→
SI/F
Ⅱ
ID
Compatible plug: 9-pin D-type Subminiature
* OMRON XM3D-0921
(Shell: XM2S-0913 <screw: #4-40 (inch)>) or equivalent
1
6
IN
DSR
2
IN
RXD
7
OUT
RTS
3
OUT
TXD
8
IN
CTS
4
OUT
DTR
9
5
*
GND
Summary of Contents for F805AT-BC
Page 1: ...F805AT BC BELT SCALE CONTROLLER 15 Feb 2019 Rev 1 03 OPERATION MANUAL...
Page 15: ...CONTENTS XIV M E M O...
Page 202: ......