![Unipulse F701+ Operation Manual Download Page 55](http://html.mh-extra.com/html/unipulse/f701/f701_operation-manual_843485055.webp)
48
5
Timing Chart for Weighing
48
Tim
in
g C
ha
rt f
or
W
eig
hin
g
Chapter
5
5-3.
Sequence control (with adjust feeding)
Near zero
Final - Set point 1
Final - Set point 2
Final
NET
Time
Judging timer
Complete
㸦
output
㸧
Judging
㸦
output
㸧
㸦
Over or go
㸧
t2
t3
Hold
t2
Comparison inhibit timer
t0
Adjust feeding timer
Final - Compensation
Over
Under
Tare subtraction
㸦
input
㸧
Start
㸦
input
㸧
SP1
㸦
output
㸧
SP2
㸦
output
㸧
SP3
㸦
output
㸧
No.2
No.1
No.3
No.4
No.6
No.5
No.7
No.9
No.10
No.12
No.8
No.13
*1
*2
*3
*4
*6
t1
t4
*5
No.9
t0: comparison inhibit time 1
t1: comparison inhibit time 2
t2: judging time
t3: complete output time
SP1: set point 1
SP2: set point 2
SP3: set point 3
Summary of Contents for F701+
Page 1: ...01AUG2020REV 1 03 WEIGHING INDICATOR F701 OPERATION MANUAL ...
Page 149: ......