![Unipulse F701+ Operation Manual Download Page 38](http://html.mh-extra.com/html/unipulse/f701/f701_operation-manual_843485038.webp)
31
4
Performing Final Discharge Control
31
Pe
rf
or
m
in
g
Fi
na
l D
is
ch
ar
ge
Chapter
4
4-6-1.
Auto free fall compensation
Select whether to enable/disable the auto free
fall compensation function.
4-6-2.
Auto free fall compensation regulation value
Set the regulation value to prevent the
compensation value from becoming too large
(or too small).
4-6-3.
Average number of times for auto free fall compensation
Set the number of times to record weighing
values so that average value can be calculated.
4-6-4.
Auto free fall compensation coefficient
This is a setting that prevents compensation
values from fluctuating by multiplying
coefficient of 1 or below.
4-7.
Comparison setting
Functions and settings to make the final
discharge control more convenient are described below.
4-7-1.
Near zero comparison mode
This function detects that the weight value is a
value near zero. Near zero can be arbitrarily set.
Comparison condition is selected depending on
near zero comparison mode. ("
" lights up
when near zero signal is ON.)
The compensation function will not work if number of times for judging is set to zero
times (no judging). Set the number of times for judging to once or more when using
auto free fall compensation function.
Values of number of times for auto free fall and free fall compensation counter
become 0 when compensation setting value is changed.
Auto free fall coefficient can be selected from 1/4, 2/4, 3/4 and 1.
Select 1 for weighing where the weighing value remains nearly the same every time
and 1/4 to 2/4 for weighing where the weighing value fluctuates every time so that
free fall compensation value can be calculated more precisely.
Key point
[Weighing function 3] (Setting mode 2-3)
1: Auto free fall compensation ON
0: Auto free fall compensation OFF
Auto free fall compensation
[Auto free fall compensation regulation value]
(Input range: 0 to 99999)
(Setting mode 1-7)
[Weighing function 3] (Setting mode 2-3)
(Input range: 1 to 9)
[Weighing function 3] (Setting mode 2-3)
3: Auto free fall compensation coefficient 1/4
2: Auto free fall compensation coefficient 2/4
1: Auto free fall compensation coefficient 3/4
0: Auto free fall compensation coefficient 1
Auto free fall compensation coefficient
[Weighing function 1] (Setting mode 2-1)
4: Comparison OFF
3: |Net weight|
2: |Gross weight|
1: Net weight
0: Gross weight
[Near zero] (Setting mode 0-3)
(Input range: 0 to 99999)
Near zero comparison mode