37
5
FUNCTION SETTINGS
37
FU
N
C
TI
O
N
S
ET
TI
N
G
S
Chapter
5
■
Tare setting (setting mode 1-8)
A value exceeding the capacity or a scale interval falling below the min scale division cannot be
input.
(Input range/0 - 99999)
5-15.
Tare weight display (setting mode 1-9)
This function displays the current tare weight. The tare weight displayed here is a result with one-
touch tare subtraction and digital tare subtraction (preset tare weight) taken into consideration.
5-16.
Key invalid (setting mode 3-5)
Function keys on the front panel can be disabled to prevent misoperation by key operation.
- [TARE] key
(Select from 0: Invalid/1: Valid)
- [TARE RESET] key
(Select from 0: Invalid/1: Valid)
- [ZERO] key
(Select from 0: Invalid/1: Valid)
- [GROSS/NET] key
(Select from 0: Invalid/1: Valid)
One-touch tare subtraction and digital tare subtraction (preset tare weight) work
independently. Even when the preset tare weight setting is ON, one-touch tare
subtraction is immediately performed to zero the net weight value by pressing the
key.
Point
- If the tare weight is 0, "
" goes out.
- If the tare weight is other than 0, "
" lights.
- If (tare weight by one-touch tare subtraction) - (tare weight by digital tare
subtraction) = 0, "
" goes out.
Point
Key invalid
[ZERO] key
0: Invalid
1: Valid
[TARE] key
0: Invalid
1: Valid
[GROSS/NET] key
0: Invalid
1: Valid
[TARE RESET] key
0: Invalid
1: Valid