5.COMPARISON SETTING
22
■
Availability of fall compensation/ Fall compensating coefficient/
Average count of fall compensation
Variations in fall, which is a major cause of errors in weighing, are automatically compensated by this
function for accurate weighing.
AFFC
Alternatives:
[
OFF
]
[
ON
]
CPS.COEFFICIENT Alternatives:
[
1/1
]
[
3/4
]
[
2/4
]
[
1/4
]
AVG.CNT OF AFFC
Setting range:
1 to 9 (times)
Principle of automatic fall compensation
Differences (D) between the value set at the final weight and actually weighed value are recorded by
the predetermined number of times (preset number of times) (A) to calculate a mean value, which is
multiplied by the compensating coefficient (C), and the value is added to or subtracted from the preset
fall value.
In order to minimize the errors, the values of D (D
1
, D
2
, D
3
, ... D
A
) can also be regulated.
Setting of automatic fall parameters
AFFC
Select whether or not to use the automatic fall compensating function.
AFFC REGULATION VAL
Set the regulation value to prevent the compensation value from
becoming extremely large (or small). (Each code)
AVG.CNT OF AFFC
Set the number of times of recording the weighed value to calculate a
mean value.
CPS.COEFFICIENT
Set to prevent variations in compensation value through multiplication
by a coefficient of 1 or less.
FINAL – SP1
FINAL – SP2
FINAL – CPS
FINAL
NET
NEAR ZERO
0
Time
STAB output
END output
Completion
ON
ON
Completionl output time setting
OVER
UNDER
output time
Value to be added to or subtracted from the preset fall value.
(D
1
+
D
2
+
D
3
・
・・
・
・・
D
A
)
A
× C