86
12
Interface
86
In
te
rf
ac
e
Chapter
12
■
Transmitting format for continuous transmission/printing
- Transmitting format 1
- Transmitting format 2
*: When analog peak hold (peak hold selection = 1: analog, and hold mode = 1: peak hold) is used,
the 5 digits will be the same as the linked indicated values.
*1
O: Overload
(LOAD,OFL,OVERLOAD)
S: Stable
M: Unstable
H: Hold
Priority: H
>
O
>
(S or M)
*4
N: Near zero OFF
Z: Near zero ON
*5
H: HH limit ON
L: LL limit ON
G: HH limit and LL limit OFF
N: HH limit and LL limit ON
F: Compare OFF
Priority: N
>
(H or L) F
>
G
*2
A: Zero tracking OFF
T: Zero tracking ON
*3
H: HI limit ON
L: LO limit ON
G: HI limit and LO limit OFF
N: HI limit and LO limit ON
F: Compare OFF
Priority: N
>
(H or L) F
>
G
*6
Decimal place
3: 0.000
2: 00.00
1: 000.0
0: None
0 1 2
3 4 5
6 7
8 9 10 11 12 13 14 15 16 17 18 19
G S
,
*1
*2
*3
*4
,
,
,
,
Linked indicated value
Sign
+
or
-
±
*5 ,
20 21 22
23
ID
Terminator
(5 decimal point)
0 1 2
3 4 5
6 7
8 9 10 11 12 13 14 15 16 17 18 19 20 21
W T
*1 *2 *3 *4
±
Non-linked indicated
Sign
+
or
-
Linked indicated
*5
SOH
STX
ETX BCC
Sign
+
or
-
±
*6
22 23 24 25
ID
BCC calculation range
Each ASCII code of SOH, STX, ETX
SOH: 01
STX: 02
ETX: 03
BCC calculation method
For BCC,
each code in the BCC calculation range
is represented in hexadecimals
and is XORed with all data.
value (5 digits)
value (5 digits)*
Do not specify continuous mode when there are multiple F325s connected.
Attention