6.FUNCTIONS
81
6-12-7. Over/under comparison mode
Setting /
3 : Comparison, holding the weight value, when the complete output is ON
2 : Comparison when the complete output is ON
1 : Comparison when the external judgment input is ON
0 : Continuous comparison
CC-Link
0
27
MSB
LSB
RWw0006
RWw0005
RWw0004
Write the code No. and set value.
remote register
H
L
0
0 to 3
Code No.
Set value
Word size
Console
1) Select code 27.
2) Press the ENT key, and then set the
comparison mode.
3) Determine the setting with the ENT key.
Over/Under
comparison mode