6.FUNCTIONS
73
6-12-3. Simple Comparison Control and Sequence Control
Simple Comparison Control
Compares weight value with discharging value regulerly.
Output is always ON when the weight value satisfies the conditions of final discharging setting
items.
In simple comparison control, the next weighing is judged to be possible when the weight falls
short of 25% of the Final after completion of the previous weighing.
Sequence Control
This is a control method which compares the weight value with discharging value after starting
signal of weighing ON.
When the starting signal ON, output of each signal of Set Point 1, Set Point 2, and Final turns
ON then the signal turns OFF after weight value satisfied the each condition.
Sequential control can be conducted without connecting external sequencer in sequence control.
For details, see "6-13.Sequence Control" on p.91.
Summary of Contents for F156
Page 1: ...F156 WEIGHING CONTROLLER 07 JUN 2012 REV 1 40 OPERATION MANUAL CC Link Ver 1 10...
Page 115: ...7 REMOTE CONSOLE UNIT 106 Monitor change Change the display with the key...
Page 120: ...7 REMOTE CONSOLE UNIT 111 Monitor change Change the display with the keys 0 to 9 1 2 3 4 5 0...