6.FUNCTIONS
95
6-13-2. Sequence with adjust feeding valid
●
Set adjust feeding ON/OFF in the sequence mode of setting code 51 to ON.
●
The complete signal output timing depends on the setting of the complete output mode of
setting code 26.
●
Over/under comparisons are made, holding the weight value, when the complete output is
ON, deregarding the setting of over/under comparison mode of setting code 27.
●
Upper/lower limit comparisons are always made deregarding the setting of the upper/lower
limit comparison 2 of setting code 28.
t1 : Comparison inhibit time; comparison inhibit time of setting code 10
t2 : Judging time; judging time of setting code 11
t3 : Complete output time; complete output time of setting code 12
t4 : Adjust feeding time; adjust feeding time of setting code 13
Start
Stop
SP1
SP2
SP3
ON
ON
ON
ON
OFF
t1
Complete
Comparison
Complete output time
t3
t1
t2
t2
t4
Judgment
Judging time
Adjust
ON
(Over or Go)
inhibit time
feeding time