![background image](http://html2.mh-extra.com/html/unipulse/f156/f156_operation-manual_3889947103.webp)
6.FUNCTIONS
94
Weight value confirmation at the sequence mode
Confirm whether the weighing value has reached SP1 at the start of weighing.
(select from ON or OFF) If it has, “Sequence error 5” will be displayed.
Refer to "6-12-4.Final / Set point2 / Set point1 / Compensation / Over / Under" on p.75
concerning Set Point 1 setting.
Setting /
1 : Valid
0 : Invalid
CC-Link
0
53
MSB
LSB
RWw0006
RWw0005
RWw0004
Write the code No. and set value.
H
L
0
0 to 1
Word size
remote register
Set value
Code No.
Console
1) Select code 53.
2) Press the ENT key, and then set the
weight value confirmation.
3) Determine the setting with the ENT key.
Weight value
confirmation
Summary of Contents for F156