10.CAUTION ABOUT POWER CONSUMPTION AND SYSTEM CONFIGURATION
26
10. CAUTION ABOUT POWER CONSUMPTION
AND SYSTEM CONFIGURATION
Design your system with sufficient consideration given to power consumption so that the total
power consumption of the F130 and units of the CJ series (CPU unit, Configuration units, etc.) does
not exceed the maximum supply capability of the power supply unit.
F130 power consumption: 0.46 [A]
The number of connectable units is up to 10 units per CPU rack
*
according to the specifications of
the CJ series. (It can be expanded to 40 units depending on the CPU unit.)
* The CJ-series CPU rack consists of a CPU unit, power supply unit, configuration units (Basic I/O
units, Special I/O units(F130 included), and CPU bus units), and an end cover.
For the system configuration of the CJ series and the power consumption of each
unit, see "OMRON CJ series: CJ1/CJ1-H/CJ1M CPU Unit User's Manual (Setup),"
etc.