4
Advanced use
72
4-4-1. Range over (U/L)
If the limits set by Target Value Ach (Bch) and Target Range Ach (Bch) are exceeded, the following are
additionally recorded in the STATE column: "U" for upper limit over and "L" for lower limit over.
■
If "range over" (U/L) and "over status" (R: See the previous page.) occur simultaneously, "over
status" (R) is recorded.
■
"Range over" is a index for users to know whether or not the recorded value exceeds the limits. It
does not affect sub totals/grand totals.
4-5.Deletion records
Use this function for deleting recorded data (not to add it to sub totals/grand totals). Only the
previously recorded one piece of data can be deleted.
In the recording mode, press the
→
key for deletion.
■
Only the previously recorded one piece of data can be deleted.
■
The latest data at the time of pressing the
key is deleted.
■
Deletion cannot be performed twice or more in succession.
■
In case of both recording, deletion is performed on both Ach and Bch.
0
80
100
120
Lower
Upper
L recorded
U recorded
(Example) When Target Value is set at 100,and Range at 20
55.
0kgL etc
150.0kgU etc
limit value
limit
Target
'U' recorded
Weighed value > Target value + Target range
'L' recorded
Weighed value < Target value - Target range