SETTINGS AND CALIBRATIONS
57
SETTINGS AND CAL
IBRATIONS
Chapter
4
- Change of Section
Select whether Change of Section is made by External Input or
Setting.
Operation
Setting range (External Input or Setting)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Change (Change of Sct.)
- Number of Use Sections
Set the number of sections to take hold.
Operation
Setting range (1 to 5)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Change (Use Sct.)
- Section No.
Select the section(s) to set. Selection can be made by the number of
sections set under “Number of Use Sections.”
Operation
Setting range (Sct. 1, Sct. 2, Sct. 3, Sct. 4, Sct. 5)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Sct. 1 to Sct. 5
- Use Hold
Set the hold to detect judgment point(s).
* End displacement can be set only final section among the sections
set by "Number of Use Sections" when X-axis of wave form is
displacement.
Setting range
(Always, Sample, Peak, Bottom, Peak to Peak, Relative Maximum,
Operation
Relative Minimum, Inflection Point, Average, End Displacement)
Main screen
→
Setting
→
Work Setting
→
Hold Setting
→
Use Hold
When the Waveform Reference is set at Back, Change of Section cannot be
made externally.
Point
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......