10
2
INSTALLATION AND CONNECTION
10
INST
ALLATION AND CONNECT
ION
Chapter
2
2-2.
Sensor connection
■
Connection of analog input/output terminals
How to connect
1.
Strip 5mm of the covering of the wire to be
connected.
The size of connectable wires is from 0.21 to
3.31mm
2
(AWG12 to 24).
2.
Twist the tip to such an extent that it will not spread out.
3.
Loosen the screw with a screwdriver to open
the connection hole.
A Phillips screwdriver 3 to 3.5mm #1 in shaft diameter
is recommended. (Precision screwdriver, etc.)
4.
Insert the wire into the connection hole so as
not to let the tip spread out.
5.
Tighten the screw with the screwdriver.
0.5Nm of tightening torque is recommended.
6.
Lightly pull the wire to make sure that it is
securely clamped.
7.
Insert the wire-connected plug into the F381A
body, and tighten the screws (two).
How to remove the terminal block
1.
Loosen the screws (two) with a screwdriver.
2.
Remove the terminal block by giving it a
strong pull.
5mm
Loosen.
(Turn
Tighten.
(Turn clockwise.)
Pin No. 1
Pin No. 12
Adaptable plug ETB42-12P
counterclockwise.)
Tighten.
(Turn clockwise.)
Tighten.
(Turn clockwise.)
Pin No.1
Pin No.12
Loosen.
(Turn
Loosen.
(Turn
counterclockwise.)
counterclockwise.)
When installing the terminal block to the F381A body,
check its orientation. (See the illustration at the right.)
Attention
Insert side
Right side
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......