29
C o n f i g u r i n g
t h e L a p t i m e r
Setup mode
This illustration
shows the warning
LED setting in a
graphical way.
Warning above
is the maximum
value.
Warning below
is
the minimum value.
The
ignore below
value can be used
to avoid constant
low warnings.
Channel:
The channel is the most important
setting. A popup lets you select the channel
you want to use for the warning.
Warning above:
The maximum value of the
channel before the warning LED is active.
When the channel gets above this value, it will
warn you.
Warning below:
The minimum value of the
channel before the warning LED is active.
When the channel gets below this value, it will
warn you.
Ignore below:
If the minimum value is set,
the ignore under value can be used too. To
avoid a constant warning when the channel
value is below the minimum warning, this
setting will ignore the warning below a certain
value. This is typically used for engine water
temperature warning.
LED warning:
The blink types are “constant”,
“slow” and “fast”. Fast is typically used by the
shift light, so if that is enabled, try to avoid it
for the warnings.
Example on a more complex warning LED
setup. Here all the settings are used.
In the example above, all the settings are used
for the temperature 1 channel. Here we can
see that this channel is used for the cylinder
temperature. Programming the warning like
this will give the following warning.
The LED will blink slowly when the tempera-
ture is between 45 and 70 °C and then again
if the temperature is above 85 °C.
Please notice that the same channel can
be used for more warning LEDs.
LED BRIGHTNESS
The LEDs’ brightness can be adjusted from 0%
to 100%.
The LEDs are very powerful and running them
at high brightness can be dangerous for your
eyes. Always keep them at the lowest bright-
ness level, but still visible at full sunlight. Do
never look directly into them!
LAST LAP DATA
When the start/finish line is passed, the Lapti-
mer can show different information on the last
lap. Here is a short explanation on what the
settings does.
Off:
No special data values are shown when
passing the start/finish line. Everything work-
ing like normal.
Max. values:
The maximum values from the
previous lap are shown when passing the start/
finish line. Please notice that not all channels
have maximum values. An example is the gear
channel.
Summary of Contents for 03-05-001
Page 6: ...VI This page was intentionally left blank...
Page 10: ...10 I n t r o d u c t i o n Examples...
Page 34: ...34 Setup mode C o n f i g u r i n g t h e L a p t i m e r...
Page 55: ...55 I n d e x...
Page 56: ...Unipro ApS Viborg Hovedvej 24 DK 7100 Vejle Denmark Tel 45 7585 1182 www uniprolaptimer com...