a 12-bit measurement at a resolution of 0.0625°C.
MAX6633 slave address
BIT
7
6
5
4
3
2
1
0
HEX ADDRESS
RANGE
0x80 – 0x8E
VALUE
1
0
1
0
GA2 GA1 GA0
0
For further information or support in using the I²C serial bus features incorporated into the TPCMQ48
series please contact applications support.
21.0 TROUBLESHOOTING GUIDE
21.1 If you encounter difficulties in getting a TPCMQ48 module or complete power system
to operate properly please check all connections carefully and use the following as a
troubleshooting guide.
a) If the INPUT GOOD LED is ON, the OUTPUT GOOD LED is OFF and there is no
voltage on the output then the unit will be inhibited. To enable the unit make sure that
the Inhibit input is connected to the +5V Standby supply.
b) If the INPUT GOOD LED is ON, the OUTPUT GOOD LED is OFF and the voltage
on the output is low then the output has been set below the DCOK detection point. If
the remote adjust feature is being used ensure that the control voltage is set at a level
sufficient to bring the output voltage within limits.
c) If both LEDs are OFF and the +5V standby supply is present then there is a fault with
the unit and it should be returned for repair.
d) If both LEDs are OFF and the +5V standby supply is present then the input supply is
not reaching the unit. Check that any breakers in the supply side have not tripped.
Please note that there are no user serviceable parts inside either the modules or the shelves and that
opening either will void the warranty.
If you are still unable to resolve any problem call your nearest UNIPOWER sales office for support:
US +1 954 346 2442
UK +44 (0)1903 768200