27
Kind 1 (39-48)
Item
Description
Default
Instruction
39
System speed dialling table for over class
of service (OCS):
OCS=0: 0 1 2 3 4 5 6 7 8 9
OCS=1:
OCS=2:
OCS=3:
OCS=4:
OCS=5:
OCS=6:
OCS=7:
OCS=8: 0 1 2 3 4 5 6 7 8 9
OCS=9:
---
Each table has 10 groups, Group "0" is included
00, 01..09; Group "1" is included 10….19.
OCS 0: 0123456789
9:0123456789
Related programs: K1 item70, K2 item 39- 40
Application: If there’re telephone numbers allow all
the users, even though the class of service on
intercom, to call it. Eg. The factory director’s
telephone number or boss’s number.
Operation: Press hash key “#” and press the group
number. Eg.: #01
40 Manager password
0000
0000: Invalidity
Available code: 4 digits
The top priority of password that allows to dial out
any class of call even beyond the station class.
41 RS-232 baudrate
1200
300-19200 BPS
If install K9111C card, it has the isolated circuit
interface. (Max. 4800 BPS)
42 RS-232 transmission form
34567
34567 is 8 bit, 2 stop bit, even parity.
Description
:
0 DSR, DTR no check
x
1 RTS, CTS no check
x
2 MODEM
x
3 Even parity
x Odd parity
4 Enable parity
x No parity
5 2 stop bit
x 1 stop bit
67 8 bit
6x 7 bit
43
Interval time of warning tone when handset
is not well on-hook
0
0-9999 seconds
0 : Not available
When the station is off-hook, the warning tone will
be heard for each setting interval time.
44 Music source on hold
1
For ISDK-26 Basic
:
0: From external source
1: From Music IC of MPU card
Related program: K8
0
For ISDK-26 Plus:
0: From self-recording music DSP card
1: From Music IC of MPU card
3: From DSP (F9858)
45 Interval time of auto-redial
20
0-9999 seconds
46 Frequency of auto-redial
9
0-200 times
47
SLT pulse interval between code and
code dialing
100
10-9999 x 3.333 ms (SLT to PBX)
48 The shortest time of SLT flash
50
10-9999 x 3.333 ms
The shortest flash time when the single line
telephone pressed "HOOK"/”FLASH”